IN-VIVO TRANSPORT AND EXCRETION OF CORROSION PRODUCTS FROM ACCELERATED ANODIC CORROSION OF POROUS-COATED F75 ALLOY

被引:24
作者
BROWN, SA [1 ]
ZHANG, K [1 ]
MERRITT, K [1 ]
PAYER, JH [1 ]
机构
[1] CASE WESTERN RESERVE UNIV,DEPT MAT SCI & ENGN,CLEVELAND,OH 44106
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1993年 / 27卷 / 08期
关键词
D O I
10.1002/jbm.820270806
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Corrosion of porous coated cobalt chromium specimens surgically implanted subcutaneously in hamsters was accelerated by application of a fixed anodic potential. Corrosion current measurements were utilized for prediction of metal ion release based on Faraday's law. Daily urine samples were collected pre- and post-stimulation, and, at animal sacrifice, organs and blood samples were taken for chemical analysis. By using in vitro release data from previous studies, and efficiency correction factors, the amount of metal ion release was calculated. The results demonstrated rapid and complete excretion of nickel and molybdenum. Most of the cobalt was excreted, with elevation of cobalt levels in liver, kidney, and lung. Chromium excretion was much lower due to significant red cell binding and in vivo storage, especially in the kidney and spleen. (C) 1993 John Wiley & Sons, Inc.
引用
收藏
页码:1007 / 1017
页数:11
相关论文
共 30 条
[1]  
Altman PL, 1979, INBRED GENETICALLY 2
[2]   CHROMIUM CONCENTRATIONS IN SERUM, BLOOD CLOT AND URINE FROM PATIENTS FOLLOWING TOTAL HIP-ARTHROPLASTY [J].
BARTOLOZZI, A ;
BLACK, J .
BIOMATERIALS, 1985, 6 (01) :2-8
[3]   SERUM CONCENTRATIONS OF CHROMIUM, COBALT AND NICKEL AFTER TOTAL HIP-REPLACEMENT - A 6 MONTH STUDY [J].
BLACK, J ;
MAITIN, EC ;
GELMAN, H ;
MORRIS, DM .
BIOMATERIALS, 1983, 4 (03) :160-164
[4]   INVITRO AND INVIVO METAL-ION RELEASE [J].
BROWN, SA ;
FARNSWORTH, LJ ;
MERRITT, K ;
CROWE, TD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (04) :321-338
[5]  
BROWN SA, 1987, BIOMATERIALS CLIN AP, P717
[6]   EXCESSIVE METAL RELEASE DUE TO LOOSENING AND FRETTING OF SINTERED PARTICLES ON POROUS-COATED HIP PROSTHESES - REPORT OF 2 CASES [J].
BUCHERT, PK ;
VAUGHN, BK ;
MALLORY, TH ;
ENGH, CA ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (04) :606-609
[7]   CONCENTRATION OF WEAR PRODUCTS IN HAIR, BLOOD, AND URINE AFTER TOTAL HIP REPLACEMENT [J].
COLEMAN, RF ;
HERRINGTON, J ;
SCALES, JT .
BMJ-BRITISH MEDICAL JOURNAL, 1973, 1 (5852) :527-529
[8]  
CRACCHIOLO A, 1982, CLIN ORTHOP RELAT R, V170, P169
[9]  
DORR LD, 1990, CLIN ORTHOP RELAT R, V261, P82
[10]   CHARACTERISTICS OF TRACE IONS RELEASED FROM EMBEDDED METAL IMPLANTS IN THE RABBIT [J].
FERGUSON, AB ;
AKAHOSHI, Y ;
LAING, PG ;
HODGE, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1962, 44 (02) :323-336