SHORT-TERM STABILITY OF LASER-PUMPED RUBIDIUM GAS CELL FREQUENCY STANDARD

被引:14
作者
SABURI, Y
KOGA, Y
KINUGAWA, S
IMAMURA, T
SUGA, H
OHUCHI, Y
机构
[1] Research Laboratory, Anritsu Corporation, Atsugi, 1800 Onna
关键词
FREQUENCE STABILITY; STANDARDS;
D O I
10.1049/el:19940461
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The authors examine the influence of the light-shift effect on the frequency stability of a laser-pumped Rb gas cell standard for averaging time up to 10(4)s. The measured stability at the flicker floor is 7 x 10(-14) for averaging times from 200 to 5000s, providing that the laser frequency is properly set at the optical resonance frequency, and correcting for the variation of atmospheric pressure.
引用
收藏
页码:633 / 635
页数:3
相关论文
共 7 条
[1]   INHOMOGENEOUS LIGHT SHIFT IN ALKALI-METAL ATOMS [J].
CAMPARO, JC ;
FRUEHOLZ, RP ;
VOLK, CH .
PHYSICAL REVIEW A, 1983, 27 (04) :1914-1924
[2]  
CAMPARO JC, 1986, J APPL PHYS, P3313
[3]   MODULATION TRANSFER AND OPTICAL STARK-EFFECT IN A RUBIDIUM ATOMIC CLOCK PUMPED BY A SEMICONDUCTOR-LASER [J].
HASHIMOTO, M ;
OHTSU, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1989, 6 (10) :1777-1789
[4]   A NOVEL METHOD TO COMPENSATE FOR THE EFFECT OF LIGHT SHIFT IN A RUBIDIUM ATOMIC CLOCK PUMPED BY A SEMICONDUCTOR-LASER [J].
HASHIMOTO, M ;
OHTSU, M .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (03) :458-462
[5]  
KINUGAWA S, 1993, INT S ATOMIC FREQUEN, P81
[6]  
LEWIS LL, 1981, 35TH P ANN FREQ CONT, P612
[7]  
SZEKELY C, 1992, SPIE S FREQ STAB LAS, V1837, P299