RATIOMETRIC CONFOCAL CA2+-MEASUREMENTS WITH VISIBLE WAVELENGTH INDICATORS IN ISOLATED CARDIAC MYOCYTES

被引:205
作者
LIPP, P [1 ]
NIGGLI, E [1 ]
机构
[1] UNIV BERN, DEPT PHYSIOL, BUEHLPL 5, CH-3012 BERN, SWITZERLAND
关键词
D O I
10.1016/0143-4160(93)90040-D
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
We present a new method for ratiometric Ca2+ measurements using indicators with excitation spectra in the visible range of wavelengths. Laser-scanning confocal microscopy was used to record intracellular Ca2+-signals with high temporal and spatial resolution in single cardiac myocytes. The patch-clamp technique was applied to load the cells with the fluorescent Ca2+-indicators and to follow the membrane currents with the fluorescence signals simultaneously. Intracellular free Ca2+-concentration ([Ca2+]i) was estimated with a ratiometric method. An in vitro calibration procedure was used to convert the fluorescence ratio obtained with two different Ca2+ indicators (Fluo-3 and Fura-Red) into Ca2+-concentrations. Fluo-3 showed an increase in fluorescence upon a rise in intracellular Ca2+-concentration, while the Fura-Red fluorescence decreased. Since the fluorescence of Fluo-3 was around 2-fold brighter than the Fura-Red signal the cells were loaded with a 1:2 mixture of the two indicators. The large increase of the fluorescence ratio during a rise in [Ca2+]i (up to 4-fold) allowed us to record time-resolved signals with this mixture even when monitored in a very small subcellular volume (around 1 mum3). Long lasting continuous recordings of the fluorescence were possible because the dye-mixture exhibited no detectable bleaching with illumination periods of up to 30 s. The use of the Fluo-3/Fura-Red ratio method should significantly facilitate and improve quantitative measurements of [Ca2+]i with high temporal and spatial resolution. Moreover, this approach is especially valuable when used with confocal microscopes which are usually equipped with lasers in the visible light range. Furthermore, it may be possible to use the same approach with mixtures of other indicators to estimate the concentration of other biologically important ions/compounds with a ratiometric calibration.
引用
收藏
页码:359 / 372
页数:14
相关论文
共 30 条
[1]   A SIMPLE METHOD FOR THE ACCURATE DETERMINATION OF FREE [CA] IN CA-EGTA SOLUTIONS [J].
BERS, DM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 242 (05) :C404-C408
[2]   INTRACELLULAR DIFFUSION, BINDING, AND COMPARTMENTALIZATION OF THE FLUORESCENT CALCIUM INDICATORS INDO-1 AND FURA-2 [J].
BLATTER, LA ;
WIER, WG .
BIOPHYSICAL JOURNAL, 1990, 58 (06) :1491-1499
[3]   HIGH-RESOLUTION MEASUREMENT AND CALIBRATION OF CA2+-TRANSIENTS USING INDO-1 IN GUINEA-PIG ATRIAL MYOCYTES UNDER VOLTAGE CLAMP [J].
CALLEWAERT, G ;
LIPP, P ;
POTT, L ;
CARMELIET, E .
CELL CALCIUM, 1991, 12 (04) :269-277
[4]   A FUZZY SUBSARCOLEMMAL SPACE FOR INTRACELLULAR NA+ IN CARDIAC-CELLS [J].
CARMELIET, E .
CARDIOVASCULAR RESEARCH, 1992, 26 (05) :433-442
[5]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[6]   INWARD CURRENT GENERATED BY NA-CA EXCHANGE DURING THE ACTION-POTENTIAL IN SINGLE ATRIAL CELLS OF THE RABBIT [J].
EARM, YE ;
HO, WK ;
SO, IS .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1990, 240 (1297) :61-81
[7]  
GRYNKIEWICZ G, 1985, J BIOL CHEM, V260, P3440
[8]  
Haugland R.P., 1992, HDB FLUORESCENT PROB
[9]   SPATIAL AND DYNAMIC CHANGES IN INTRACELLULAR CA2+ MEASURED BY CONFOCAL LASER-SCANNING MICROSCOPY IN BULLFROG SYMPATHETIC-GANGLION CELLS [J].
KUBA, K ;
HUA, SY ;
NOHMI, M .
NEUROSCIENCE RESEARCH, 1991, 10 (04) :245-259
[10]  
KUREBAYASHI N, 1992, Biophysical Journal, V61, pA160