EFFECTS OF TARGET SHAPE AND NEUTRON-SCATTERING ON ELEMENT SENSITIVITIES FOR NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS

被引:50
作者
MACKEY, EA
GORDON, GE
LINDSTROM, RM
ANDERSON, DL
机构
[1] NATL INST STAND & TECHNOL,CTR ANALYT CHEM,GAITHERSBURG,MD 20899
[2] US FDA,DIV CONTAMINANTS CHEM,WASHINGTON,DC 20204
关键词
D O I
10.1021/ac00003a019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Results are presented for a study of the effects of neutron scattering by hydrogen on element sensitivities for in-beam neutron capture prompt gamma-ray activation analysis. In a scattering matrix, sensitivities vary as a function of both the scattering density, i.e., the number of scatterers per unit volume and the magnitude of scattering cross sections, and the target geometry, i.e., the target shape and orientation with respect to the neutron beam. Element sensitivities (counts.s-1.mg-1) increased linearly with H density (g.mL-1) for H, B, Na, Cl, K, Mn, Br, Ag, Cd, I, Sm, and Gd, measured for liquids packaged in Teflon bags. Nine of the 12 elements studied had 1.69 +/- 0.18% sensitivity enhancement per percent increase in H density. Samarium sensitivity was enhanced by only 0.54 +/- 0.07%/% H, which may indicate that neutron scattering by H causes a shift in the energy distribution of the neutrons. Manganese sensitivity was enhanced by 2.44 +/- 0.26%/% H. The enhancement of the sensitivity for H itself varied with matrix composition. For several series of disk-shaped, solid, hydrogenous targets, element sensitivities increased with decreasing target thickness until, at some limiting thickness, this trend was reversed. Consistent with theory, sensitivities measured for spherical hydrogenous targets showed no enhancement.
引用
收藏
页码:288 / 292
页数:5
相关论文
共 8 条
[1]  
ANDERSON DL, 1983, NBS SPEC PUBL, V1190, P148
[2]  
CHRIEN RE, 1984, NEUTRON RAD CAPTURE, V3, P187
[3]   NEUTRON-SCATTERING AND ITS EFFECT ON REACTION-RATES IN NEUTRON ABSORPTION EXPERIMENTS [J].
COPLEY, JRD ;
STONE, CA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (03) :593-604
[4]   NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS FOR MULTIELEMENT DETERMINATION IN COMPLEX SAMPLES [J].
FAILEY, MP ;
ANDERSON, DL ;
ZOLLER, WH ;
GORDON, GE ;
LINDSTROM, RM .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2209-2221
[5]   NEUTRON SELF-SHIELDING FACTORS FOR SIMPLE GEOMETRIES [J].
FLEMING, RF .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1263-1268
[6]  
FLEMING RM, UNPUB
[7]  
KITTO ME, 1987, THESIS U MARYLAND
[8]   SLOW-NEUTRON MULTIPLE-SCATTERING [J].
SEARS, VF .
ADVANCES IN PHYSICS, 1975, 24 (01) :1-45