IMPROVED REPRODUCIBILITY OF LEFT ATRIAL AND LEFT-VENTRICULAR MEASUREMENTS BY GUIDED 3-DIMENSIONAL ECHOCARDIOGRAPHY

被引:85
作者
KING, DL
HARRISON, MR
KING, DL
GOPAL, AS
MARTIN, RP
DEMARIA, AN
机构
[1] UNIV KENTUCKY, COLL MED, DIV CARDIOL, LEXINGTON, KY 40506 USA
[2] EMORY UNIV, SCH MED, SCH MED, DIV CARDIOL, ATLANTA, GA 30322 USA
关键词
D O I
10.1016/0735-1097(92)90383-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The objective of this study was to determine whether guided three-dimensional echocardiography could improve the reproducibility of left atrial and left ventricular antero-posterior measurements over that of standard unguided two-dimensional echocardiography. Background. Although these measurements are standard indexes for evaluating chamber size, their use is limited by significant interobserver variability largely due to variable image plane positioning. To improve measurement accuracy and reproducibility, we have developed a three-dimensional echocardiograph that displays the line of intersection of the real-time image with a previously saved orthogonal reference image. This display shows the relation of the real-time image to anatomic landmarks in its third, nonvisualized dimension and may be used to guide image positioning. Methods. Three pairs of operators independently performed unguided two-dimensional and guided three-dimensional examinations on three groups of 10 patients each. The left atrium was measured in a plane through the inferior surface of the aortic cusps and the left ventricle in a plane perpendicular to its long axis 1 cm below the mitral leaflet tips. Interobserver variability of these measurements on unguided parasternal long-axis images and on guided short-axis images was assessed. Results. The standard unguided two-dimensional examination was associated with an interobserver variability of 14.6% and 9.1% for atrial and ventricular measurements, respectively. Guided three-dimensional echocardiography significantly reduced interobserver variability to 5.0% and 3.1%, respectively, for the same measurements (p < 0.005 by McNemar's test). Conclusions. Significant interobserver variability occurs with standard unguided two-dimensional echocardiographic measurement of left atrial and left ventricular dimensions. Guided three-dimensional echocardiography achieves a nearly threefold improvement of reproducibility of these measurements and provides the basis for improved serial evaluation and comparison of atrial and ventricular size by different operators.
引用
收藏
页码:1238 / 1245
页数:8
相关论文
共 17 条
  • [1] FEIGENBAUM H, 1986, ECHOCARDIOGR-J CARD, P154
  • [2] DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION OF THE INTACT HUMAN LEFT-VENTRICLE - TECHNIQUE AND INITIAL OBSERVATIONS IN PATIENTS
    GEISER, EA
    ARIET, M
    CONETTA, DA
    LUPKIEWICZ, SM
    CHRISTIE, LG
    CONTI, CR
    [J]. AMERICAN HEART JOURNAL, 1982, 103 (06) : 1056 - 1065
  • [3] 3-DIMENSIONAL RECONSTRUCTION OF ECHOCARDIOGRAPHIC IMAGES USING THE ROTATION METHOD
    GHOSH, A
    NANDA, NC
    MAURER, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (06) : 655 - 661
  • [4] Gopal A S, 1992, J Am Soc Echocardiogr, V5, P115
  • [5] REPRODUCIBILITY OF LEFT-VENTRICULAR VOLUMES BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    GORDON, EP
    SCHNITTGER, I
    FITZGERALD, PJ
    WILLIAMS, P
    POPP, RL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (03) : 506 - 513
  • [6] HARRISON MR, 1990, J AM SOC ECHOCARDIOG, V3, P228
  • [7] REPORT OF THE AMERICAN-SOCIETY-OF-ECHOCARDIOGRAPHY COMMITTEE-ON-NOMENCLATURE-AND-STANDARDS-IN-2-DIMENSIONAL-ECHOCARDIOGRAPHY
    HENRY, WL
    DEMARIA, A
    GRAMIAK, R
    KING, DL
    KISSLO, JA
    POPP, RL
    SAHN, DJ
    SCHILLER, NB
    TAJIK, A
    TEICHHOLZ, LE
    WEYMAN, AE
    [J]. CIRCULATION, 1980, 62 (02) : 212 - 217
  • [8] REPRODUCIBILITY OF QUANTITATIVE TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    HIMELMAN, RB
    CASSIDY, MM
    LANDZBERG, JS
    SCHILLER, NB
    [J]. AMERICAN HEART JOURNAL, 1988, 115 (02) : 425 - 431
  • [9] 3-DIMENSIONAL SPATIAL REGISTRATION AND INTERACTIVE DISPLAY OF POSITION AND ORIENTATION OF REAL-TIME ULTRASOUND IMAGES
    KING, DL
    KING, DL
    SHAO, MYC
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1990, 9 (09) : 525 - 532
  • [10] KING DL, 1991, J ULTRAS MED, V10, P77