TENSAMMETRIC TECHNIQUES FOR ELECTROANALYSIS

被引:12
作者
LUKASZEWSKI, Z
机构
[1] Institute of Chemistry, Technical University of Poznan, Poznan, PL-60-965
关键词
ALTERNATING CURRENT TENSAMMETRY; PULSE TENSAMMETRY; SQUARE WAVE TENSAMMETRY; KALOUSEK COMMUTATOR TECHNIQUE; DERIVATIVE CHRONOPOTENTIOMETRY;
D O I
10.1002/elan.1140050503
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The following tensammetric schemes, alternating current (ac) polarography of fundamental harmonic and second harmonic, phase-sensitive ac, square wave tensammetry, differential pulse and normal pulse tensammetry, Kalousek commutator technique, derivative chronopotentiometry, and several other techniques, are reviewed. Thermodynamic background and kinetic limitations of tensammetric analytical signals are discussed. Special attention is given to the behavior of mixtures and to the consequences of association of the analyte as well as to applications of different tensammetric techniques.
引用
收藏
页码:375 / 384
页数:10
相关论文
共 124 条
[1]  
ALBOTA LA, 1974, KOLLOID ZH, V36, P1022
[2]  
ALSLEBEN H, 1971, FASERFORSCH TEXTILTE, V22, P581
[3]   TRANSIENT ELECTROCHEMICAL TECHNIQUES IN LIQUID-CHROMATOGRAPHY WITH MICROPROCESSOR-BASED INSTRUMENTATION [J].
ANDERSON, JE ;
BOND, AM ;
HERITAGE, ID ;
JONES, RD ;
WALLACE, GG .
ANALYTICAL CHEMISTRY, 1982, 54 (11) :1702-1705
[5]   TENSAMMETRY WITH ACCUMULATION ON THE HANGING MERCURY DROP ELECTRODE .1. THE INFLUENCE OF PRECONCENTRATION POTENTIAL ON THE ACCUMULATION OF POLY(ETHYLENE GLYCOLS) WITH VARIOUS MOLECULAR-WEIGHTS [J].
BATYCKA, H ;
LUKASZEWSKI, Z .
ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) :207-214
[6]   TENSAMMETRY WITH ACCUMULATION ON THE HANGING MERCURY DROP ELECTRODE .2. THE BEHAVIOR OF MIXTURES OF POLY(ETHYLENE GLYCOLS) AS AN EXAMPLE OF SURFACTANT MIXTURES [J].
BATYCKA, H ;
LUKASZEWSKI, Z .
ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) :215-225
[7]   THE FARADAIC ADMITTANCE OF ELECTROCHEMICAL PROCESSES .1. APPARATUS SUITABLE FOR PHASE ANGLE MEASUREMENT [J].
BAUER, HH ;
ELVING, PJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1960, 82 (09) :2091-2094
[8]   COMPARISON OF THE UTILITY OF SEVERAL TENSAMMETRIC TECHNIQUES FOR THE DETERMINATION OF TRACES OF SURFACTANTS AFTER PRECONCENTRATION AT THE HANGING MERCURY DROP ELECTRODE [J].
BEDNARKIEWICZ, E ;
KUBLIK, Z .
ANALYTICA CHIMICA ACTA, 1985, 176 (OCT) :133-142
[9]   THE INFLUENCE OF ACTIVATED-CHARCOAL ON THE CURRENTS OBTAINED IN SEVERAL ELECTROANALYTICAL TECHNIQUES AT MERCURY-ELECTRODES [J].
BEDNARKIEWICZ, E ;
KUBLIK, Z .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 165 (1-2) :195-206
[10]   DETERMINATION OF TRACES OF SURFACTANTS IN DISTILLED, POTABLE AND UNTREATED WATERS AND IN SUPPORTING ELECTROLYTES BY TENSAMMETRY WITH ACCUMULATION ON THE HMDE [J].
BEDNARKIEWICZ, E ;
DONTEN, M ;
KUBLIK, Z .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 127 (1-3) :241-253