NEEDLE ASPIRATION LUNG-BIOPSY - REEVALUATION OF THE BLOOD PATCH TECHNIQUE IN AN EQUINE MODEL

被引:24
作者
MOORE, EH [1 ]
SHELTON, DK [1 ]
WISNER, ER [1 ]
RICHARDSON, ML [1 ]
BISHOP, DM [1 ]
BROCK, JM [1 ]
机构
[1] UNIV WASHINGTON,SCH MED,DEPT RADIOL,SEATTLE,WA 98195
关键词
BIOPSIES; COMPLICATIONS; TECHNOLOGY; LUNG; BIOPSY; PNEUMOTHORAX;
D O I
10.1148/radiology.196.1.7784564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To reexamine the blood patch technique in a laboratory model of lung biopsy free of confounding clinical variables. MATERIALS AND METHODS: An equine model of lung biopsy was developed with an excised lobe connected to an insufflation bulb and pressure monitor. Patched and control unpatched punctures were made in the lung surface, and the pressure within the lung was raised to the maximum achievable. Whether air leakage from the puncture sites could be induced was determined and, if so, at what pressure it occurred. RESULTS: At statistical analysis with the Kaplan-Meier test and the Cox proportional hazards regression model, the difference between failure of the patched and unpatched punctures was statistically significant (P < .0001). CONCLUSION: The blood patch technique is effective in the laboratory setting and deserves reevaluation in a clinical series with updated biopsy techniques.
引用
收藏
页码:183 / 186
页数:4
相关论文
共 8 条
[1]  
Altman, 1991, PRACTICAL STATICTS M
[2]   TRANS-THORACIC NEEDLE ASPIRATION BIOPSY - EVALUATION OF THE BLOOD PATCH TECHNIQUE [J].
BOURGOUIN, PM ;
SHEPARD, JAO ;
MCLOUD, TC ;
SPIZARNY, DL ;
DEDRICK, CG .
RADIOLOGY, 1988, 166 (01) :93-95
[3]  
GUYTON AC, 1991, TXB MED PHYSL, P403
[4]   USEFULNESS OF THE BLOOD PATCH TECHNIQUE AFTER TRANSTHORACIC NEEDLE ASPIRATION BIOPSY [J].
HERMAN, SJ ;
WEISBROD, GL .
RADIOLOGY, 1990, 176 (02) :395-397
[5]  
MCCARTNEY R, 1975, RADIOLOGY, V124, P397
[6]  
MCCARTNEY R, 1974, RADIOLOGY, V120, P872
[7]  
SURPRENANT EL, 1989, RADIOLOGY, V168, P285
[8]  
TYLER WS, 1991, EQUINE VET J, V3, P84