THE FIT OF FIXED PARTIAL DENTURES JOINED BY INFRARED SOLDERING

被引:15
作者
BYRNE, G [1 ]
LAUB, LW [1 ]
HU, JY [1 ]
LAND, MF [1 ]
机构
[1] LOYOLA UNIV,SCH DENT,DEPT DENT MAT,MAYWOOD,IL 60153
关键词
D O I
10.1016/0022-3913(92)90371-G
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study determined the accuracy of fit of three-unit fixed partial dentures joined by an,infrared soldering technique compared with one-piece fixed partial denture castings and individually cast crowns. Wax patterns of prepared Ivorine teeth, maxillary left central incisor and maxillary left canine, were injection molded; a plastic rod was used as a pontic. One group of patterns was cast as one-piece dentures, the other group was sectioned in the connector area, cast individually, and then joined by infrared soldering. Castings were seated on their respective dies, embedded in epoxy resin, and sectioned. Gap distances between the casting and the die were measured at specified marginal sites with a profile projector. Results showed that the fit of infrared-soldered fixed partial dentures was significantly better than that of one-piece castings and was comparable with the fit of single crowns. The gap openings measured in all castings were within the range of clinical acceptability.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 33 条
[1]   INERT-GAS PRE-SOLDERING OF NICKEL-CHROMIUM ALLOYS [J].
ANUSAVICE, KJ ;
SHAFAGH, I .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (03) :317-323
[2]   A QUANTITATIVE STUDY OF PREPORCELAIN SOLDERED CONNECTOR STRENGTH WITH PALLADIUM-BASED PORCELAIN BONDING ALLOYS [J].
BECK, DA ;
MOON, PC ;
JANUS, CE .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 56 (03) :301-306
[3]   EVALUATION OF MULTIPLE UNIT CASTINGS FOR FIXED PARTIAL DENTURES [J].
BRUCE, RW .
JOURNAL OF PROSTHETIC DENTISTRY, 1964, 14 (05) :939-&
[4]   CASTING ACCURACY OF HIGH-PALLADIUM ALLOYS [J].
BYRNE, G ;
GOODACRE, CJ ;
DYKEMA, RW ;
MOORE, BK .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (03) :297-301
[5]   ACCURACY OF FIXED PARTIAL DENTURES MADE BY VARIOUS SOLDERING TECHNIQUES + 1-PIECE CASTING [J].
FUSAYAMA, T ;
WAKUMOTO, S ;
HOSODA, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1964, 14 (02) :334-&
[6]   SPATIAL CHANGES OCCURRING IN FIXED PARTIAL DENTURES MADE AS ONE-PIECE CASTINGS [J].
GARLAPO, DA ;
LEE, SH ;
CHOUNG, CK ;
SORENSEN, SE .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 49 (06) :781-785
[7]   THE SEATING OF ONE-PIECE AND SOLDERED FIXED PARTIAL DENTURES [J].
GEGAUFF, AG ;
ROSENSTIEL, SF .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (03) :292-297
[8]   DISTORTIONS IN INDEXING METHODS AND INVESTING MEDIA FOR SOLDERING AND REMOUNT PROCEDURES [J].
HARPER, RJ ;
NICHOLLS, JI .
JOURNAL OF PROSTHETIC DENTISTRY, 1979, 42 (02) :172-179
[9]   IMPROVING THE CASTING ACCURACY OF FIXED PARTIAL DENTURES [J].
HINMAN, RW ;
TESK, JA ;
PARRY, EE ;
EDEN, GT .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (04) :466-471
[10]  
HOLLENBACK G M, 1965, J Calif Dent Assoc, V41, P207