EFFECTIVENESS OF INHALED BRONCHODILATOR DELIVERY SYSTEMS FOR ELDERLY PATIENTS

被引:34
作者
DIGGORY, P [1 ]
BAILEY, R [1 ]
VALLON, A [1 ]
机构
[1] CRAWLEY HOSP,CRAWLEY,W SUSSEX,ENGLAND
关键词
D O I
10.1093/ageing/20.5.379
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
A prospective study of inhaler technique using aerosol metered dose inhalers (MDIs), Rotahalers and a breath-activated device (Aerolin Autohaler) was undertaken to assess how effectively elderly patients use their inhalers. Fifty-one patients aged 67-89 years (mean 77.4 years) were enrolled. Peak flow, FEV1 and FVC were recorded, before and after inhalation of 2.5mg of salbutamol via a nebulizer, to assess the extent of reversible airways obstruction. Inhaler technique was assessed using a scoring system, based on performance in five aspects of inhaler use. Those with poor technique were randomly allocated to an alternative inhaler and reassessed. Twenty-nine of 51 patients demonstrated reversibility in their airways disease. Twenty-one of 47 had poor technique using an MDI and were given Rotahaler or Aerolin devices to use. Ten of 11 given Aerolin Autohalers improved but seven of ten using Rotahaler showed no improvement (p = 0.006). Subsequently, five of these seven were able to improve their technique with the breath-activated autohaler. The breath-activated Aerolin Autohaler is a better delivery system than Rotahalers for inhaled bronchodilators for elderly patients.
引用
收藏
页码:379 / 382
页数:4
相关论文
共 14 条
[1]   WHAT DETERMINES WHETHER AN ELDERLY PATIENT CAN USE A METERED DOSE INHALER CORRECTLY [J].
ALLEN, SC ;
PRIOR, A .
BRITISH JOURNAL OF DISEASES OF THE CHEST, 1986, 80 (01) :45-49
[2]   INHALER TECHNIQUE IN THE ELDERLY [J].
ARMITAGE, JM ;
WILLIAMS, SJ .
AGE AND AGEING, 1988, 17 (04) :275-278
[3]   HIGH-DOSE SALBUTAMOL IN CHRONIC AIR-FLOW OBSTRUCTION - COMPARISON OF NEBULIZER WITH ROTACAPS [J].
ASSOUFI, BK ;
HODSON, ME .
RESPIRATORY MEDICINE, 1989, 83 (05) :415-420
[4]  
BAUM EA, 1988, J AEROSOL MED, V1, P219
[5]   DOSE-RESPONSE STUDY OF INHALED SALBUTAMOL POWDER IN CHRONIC AIR-FLOW OBSTRUCTION [J].
CORRIS, PA ;
NEVILLE, E ;
NARIMAN, S ;
GIBSON, GJ .
THORAX, 1983, 38 (04) :292-296
[6]  
CROMPTON GK, 1982, EUR J RESPIR DIS, V63, P101
[7]   LONG-TERM COMPARISON OF SALBUTAMOL POWDER WITH SALBUTAMOL AEROSOL IN ASTHMATIC OUT-PATIENTS [J].
HARTLEY, JPR ;
NOGRADY, SG ;
SEATON, A .
BRITISH JOURNAL OF DISEASES OF THE CHEST, 1979, 73 (03) :271-276
[8]   COMPARISON OF SALBUTAMOL ROTAHALER WITH CONVENTIONAL PRESSURIZED AEROSOL [J].
HETZEL, MR ;
CLARK, TJH .
CLINICAL ALLERGY, 1977, 7 (06) :563-568
[9]  
Hodkinson H M, 1973, J R Coll Physicians Lond, V7, P305
[10]  
PATTERSON IC, 1976, BRIT MED J, V1, P76