ULTRATRACE ANION ANALYSIS OF HIGH-PURITY WATER - A COLUMN COMPARISON

被引:7
作者
MARTIN, MW
GIACOFEI, RA
机构
[1] Analytical Technology Division, Eastman Kodak Company, Rochester, NY 14650-2140
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 644卷 / 02期
关键词
D O I
10.1016/0021-9673(93)80716-L
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several vendor columns were employed in a comparison of columns aimed at optimized separation and quantitation of ultratrace (i.e., high pg/ml to low ng/ml) levels of anions in high-purity water. The anionic profile of feed water will vary depending on the source; however, anions of most interest in high-purity water applications were chromatographed. The anions tested included fluoride, acetate, formate, chloride, nitrite, bromide, nitrate, phosphate, sulfate, and oxalate. Isocratic methods were used without exception and all separations were made under chemically suppressed conditions employing a Dionex AMMS-1 suppressor with 12.5 mM sulfuric acid as regenerant. All eluents were prepared from either sodium carbonate-sodium hydrogencarbonate or 50% (w/w) sodium hydroxide solution. Columns evaluated in this study included Dionex AS4A, AS9, and AS10, Sarasep AN1 and AN2, and Waters IC-PAK Anion HR. Comparisons were made on the basis of chloride retention, resolution of fluoride and acetate, column efficiency on nitrite and sulfate peaks, capacity, and run time. Column durability was not thought to be an issue because of the nature of the samples. Dionex AS10, Sarasep AN2 and Waters IC-Pak Anion HR columns were deemed acceptable though no single column met every requirement.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 15 条
[1]  
FULMER MA, 1979, ION CHROMATOGR ANAL, V2, P381
[2]   STUDIES ON SAMPLE PRECONCENTRATION IN ION CHROMATOGRAPHY .4. EFFECT OF SAMPLE LOADING PARAMETERS ON THE PRECONCENTRATION PROCESS [J].
HADDAD, PR ;
JACKSON, PE .
JOURNAL OF CHROMATOGRAPHY, 1986, 367 (02) :301-309
[3]   STUDIES ON SAMPLE PRECONCENTRATION IN ION CHROMATOGRAPHY .1. DESIGN OF AN AUTOMATED, SINGLE PUMP PRECONCENTRATION SYSTEM WITH DIRECT UV ABSORBANCE DETECTION [J].
HADDAD, PR ;
HECKENBERG, AL .
JOURNAL OF CHROMATOGRAPHY, 1985, 318 (02) :279-288
[4]  
HADDAD PR, 1988, J CHROMATOGR, V346, P139
[5]   COMPARISON OF GRADIENT ELUTION SEPARATIONS FOR ORGANIC AND INORGANIC ANIONS WITH CHEMICALLY SUPPRESSED CONDUCTOMETRIC DETECTION [J].
HARVEY, S .
JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2) :125-137
[6]   STUDIES ON SAMPLE PRECONCENTRATION IN ION CHROMATOGRAPHY .2. AN AUTOMATED, SINGLE PUMP PRECONCENTRATION SYSTEM FOR NON-SUPPRESSED ION CHROMATOGRAPHY WITH CONDUCTIVITY DETECTION [J].
HECKENBERG, AL ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1985, 330 (01) :95-111
[7]   DETERMINATION OF INORGANIC ANIONS AT PARTS PER BILLION LEVELS USING SINGLE-COLUMN ION CHROMATOGRAPHY WITHOUT SAMPLE PRECONCENTRATION [J].
HECKENBERG, AL ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1984, 299 (01) :301-305
[8]   STUDIES ON SAMPLE PRECONCENTRATION IN ION CHROMATOGRAPHY .3. FACTORS INFLUENCING ELUENT SELECTION IN PRECONCENTRATION METHODS [J].
JACKSON, PE ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1986, 355 (01) :87-97
[9]   STUDIES ON SAMPLE PRECONCENTRATION IN ION CHROMATOGRAPHY .7. REVIEW OF METHODOLOGY AND APPLICATIONS OF ANION PRECONCENTRATION [J].
JACKSON, PE ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1988, 439 (01) :37-48
[10]   STUDIES ON SAMPLE PRECONCENTRATION IN ION CHROMATOGRAPHY .5. EFFECT OF THE ION-EXCHANGE CAPACITY OF THE CONCENTRATOR COLUMN [J].
JACKSON, PE ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1987, 389 (01) :65-74