摘要
A prosthetic caged-ball aortic valve that can be placed with transcatheter techniques was designed, constructed, and initially evaluated in 12 adult mongrel dogs. The prosthesis consisted of a ring, cage, and ball. The ring was made of stainless steel wire coiled in a springlike configuration and covered with an expandable nylon mesh. The cage consisted of a self-expanding Gianturco stent with flat stainless steel wires attached across the cranial end. The ball was a detachable latex balloon filled with a radiopaque silicone prepolymer system. The self-expanding valve was easily passed through an 11- or 12-F Teflon sheath and was placed in the ascending aorta by means of the carotid approach. The stability and efficacy of the prosthesis were evaluated radiographically for as long as the valve remained functional (1-3 hours). The competency of the valve and the patency of the coronary arteries were determined angiographically over the same period. The results of these studies indicate that development and transcatheter placement of a prosthetic aortic valve are feasible.
引用
收藏
页码:151 / 154
页数:4
相关论文
共 14 条
  • [1] COOLEY DA, 1985, CARDIAC VALVE REPLAC, pR23
  • [2] COOLEY DA, 1987, HEART VALVE REPLACEM, P105
  • [3] COOLEY DA, 1984, TECHNIQUE CARDIAC SU, P11
  • [4] PARTIAL AND COMPLETE PROSTHESES IN AORTIC INSUFFICIENCY
    HARKEN, DE
    SOROFF, HS
    TAYLOR, WJ
    LEFEMINE, AA
    GUPTA, SK
    LUNZER, S
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1960, 40 (06) : 744 - 762
  • [5] Hufnafgel CA, 1952, B GEORGETOWN U MED C, V6, P60
  • [6] INJECTION OF A SILICONE PREPOLYMER SYSTEM INTO THE GALLBLADDER OF RABBITS
    MAHON, TG
    WRIGHT, KC
    ARMENIADES, CD
    [J]. INVESTIGATIVE RADIOLOGY, 1991, 26 (10) : 902 - 905
  • [7] PERCUTANEOUSLY PLACED ENDOVASCULAR GRAFTS FOR AORTIC-ANEURYSMS - FEASIBILITY STUDY
    MIRICH, D
    WRIGHT, KC
    WALLACE, S
    YOSHIOKA, T
    LAWRENCE, DD
    CHARNSANGAVEJ, C
    GIANTURCO, C
    [J]. RADIOLOGY, 1989, 170 (03) : 1033 - 1037
  • [8] MORSE D, 1985, GUIDE PROSTHETIC CAR, P24
  • [9] PLUTH JR, 1985, CARDIAC VALVE REPLAC, P37
  • [10] RABAGO G, 1987, HEART VALVE REPLACEM, P3