RAPID ISOELECTRIC-FOCUSING OF PROTEINS IN HYDROLYTICALLY STABLE CAPILLARIES

被引:13
作者
NELSON, TJ
机构
[1] Neural Systems Section, National Institute of Neurological Disorders and Stroke, National Institues of Health, Bethesda
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 623卷 / 02期
关键词
D O I
10.1016/0021-9673(92)80376-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three new types of capillary coatings for capillary isoelectric focusing that avoid siloxane chemistry, resulting in hydrolytically stable coatings, are described and tested: phenyl-silica, acrylamide-reacted vinyl-silica, and pure PTFE. Capillaries of these three types were compared using standard proteins and a biological mixture of proteins similar to what might be encountered in actual use. Of these, the acrylamide-coated capillary produced the highest-quality results. In contrast to capillaries prepared using siloxane reactions, the capillaries described herein exhibited greatly enhanced stability at high pH.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 25 条
[1]  
Boeckman Jr R., 1978, ORG SYNTH, V58, P158
[2]   ELECTROPHORETIC SEPARATIONS OF PROTEINS IN CAPILLARIES WITH HYDROLYTICALLY STABLE SURFACE-STRUCTURES [J].
COBB, KA ;
DOLNIK, V ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :2478-2483
[3]   HIGH-SENSITIVITY PEPTIDE-MAPPING BY CAPILLARY ZONE ELECTROPHORESIS AND MICROCOLUMN LIQUID-CHROMATOGRAPHY, USING IMMOBILIZED TRYPSIN FOR PROTEIN DIGESTION [J].
COBB, KA ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2226-2231
[4]   SYNTHESIS OF A 2-DIMENSIONAL ARRAY OF ORGANIC FUNCTIONAL-GROUPS - SURFACE-SELECTIVE MODIFICATION OF POLY(VINYLIDENE FLUORIDE) [J].
DIAS, AJ ;
MCCARTHY, TJ .
MACROMOLECULES, 1984, 17 (12) :2529-2531
[5]  
EABORN C, 1960, ORGANISILICON COMPOU
[6]  
EBSWORTH EAV, 1960, VOLATILE SILICON COM, P63
[7]   CAPILLARY ZONE ELECTROPHORESIS AND ISOTACHOPHORESIS AS ALTERNATIVES TO CHROMATOGRAPHIC METHODS FOR PURITY CONTROL OF SYNTHETIC PEPTIDES [J].
FIRESTONE, MA ;
MICHAUD, JP ;
CARTER, RH ;
THORMANN, W .
JOURNAL OF CHROMATOGRAPHY, 1987, 407 :363-368
[8]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[9]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[10]   HIGH-PERFORMANCE DISPLACEMENT ELECTROPHORESIS IN 0.025-MM TO 0.050-MM CAPILLARIES COATED WITH A POLYMER TO SUPPRESS ADSORPTION AND ELECTROENDOSMOSIS [J].
HJERTEN, S ;
KIESSLINGJOHANSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :811-822