SPONTANEOUS AND DEFLECTED DRIFT-TRAJECTORIES IN ORTHOGONAL ACCELERATION TIME-OF-FLIGHT MASS-SPECTROMETRY

被引:24
作者
GUILHAUS, M
机构
[1] Department of Analytical Chemistry, The University of New South Wales, Sydney
基金
澳大利亚研究理事会;
关键词
D O I
10.1016/1044-0305(94)90009-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Orthogonal acceleration is a method for gating ions from an ion beam into a time-of-flight (TOF) mass spectrometer. The technique involves a pulsed electric field to apply acceleration directed orthogonally to an ion beam. This approach is useful for coupling continuous ion sources to TOF mass analyzers. Most instruments of this type, which have been described in the literature, use steering electrodes after the orthogonal acceleration step. Those velocity components of ions originating from the ion beam velocity are minimized so that the deflected drift-trajectory is parallel to a transverse flight tube. In an alternative geometry the ion beam velocity is conserved and the drift-trajectory after the orthogonal acceleration step is spontaneous. The differences between the space-time focusing ability with spontaneous and deflected drift-trajectories are discussed and investigated. Trajectory calculations indicate that deflection fields placed after the orthogonal acceleration step distort the ion packet because, in this geometry, the flight-time to the detector is dependent on the position that the ions enter the steering optics. Increasing the duty-cycle efficiency by sampling longer sections of the continuous ion beam leads to a degradation of resolving power. Employing a spontaneous drift-trajectory after orthogonal acceleration provides the advantage that the arrival time spread for isobaric ions is, in principle, independent of the length of the ion beam sampled. The major implication of these findings is that simultaneously optimized sensitivity and resolving power may not be achievable with the deflected drift-trajectory instruments. The calculations are in agreement with results from the published data of a number of groups who have built instruments based on the orthogonal acceleration principle.
引用
收藏
页码:588 / 595
页数:8
相关论文
共 23 条
[1]  
BENSON SW, 1960, Patent No. 2938116
[2]   HIGH-RESOLUTION TIME-OF-FLIGHT MASS SPECTROMETERS .1. EFFECTS OF FIELD DISTORTIONS IN THE VICINITY OF WIRE MESHES [J].
BERGMANN, T ;
MARTIN, TP ;
SCHABER, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (03) :347-349
[3]   HIGH-RESOLUTION TIME-OF-FLIGHT MASS SPECTROMETERS .2. CROSS BEAM ION OPTICS [J].
BERGMANN, T ;
GOEHLICH, H ;
MARTIN, TP ;
SCHABER, H ;
MALEGIANNAKIS, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10) :2585-2591
[4]   TIME-OF-FLIGHT MASS-SPECTROMETRY WITH AN ELECTROSPRAY ION-BEAM [J].
BOYLE, JG ;
WHITEHOUSE, CM .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2084-2089
[5]  
CHERNUSHEVICH IV, 1987, Patent No. 1681340
[6]  
CLAYTON E, 1992, RAPID COMMUN MASS SP, V5, P719
[7]   ORTHOGONAL ACCELERATION - A NEW DIRECTION FOR TIME-OF-FLIGHT MASS-SPECTROMETRY - FAST, SENSITIVE MASS ANALYSIS FOR CONTINUOUS ION SOURCES [J].
COLES, J ;
GUILHAUS, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (05) :203-213
[8]  
COLES JN, 1994, IN PRESS J AM SOC MA, V5
[10]   TIME-OF-FLIGHT MASS-SPECTROMETRY - AN INCREASING ROLE IN THE LIFE SCIENCES [J].
COTTER, RJ .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (08) :513-532