COMPARISON OF DIFFERENT RADIATION TYPES AND IRRADIATION GEOMETRIES IN STEREOTACTIC RADIOSURGERY

被引:53
作者
PHILLIPS, MH
FRANKEL, KA
LYMAN, JT
FABRIKANT, JI
LEVY, RP
机构
[1] Research Medicine and Radiation Biophysics Division, Lawrence Berkeley Laboratory, Berkeley, CA 94720
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 18卷 / 01期
关键词
AVM; Charged particles; Dose comparison; Photons; Stereotactic radiosurgery;
D O I
10.1016/0360-3016(90)90286-S
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Recent interest in stereotactic radiosurgery of intracranial lesions, and the development of stereotactic irradiation techniques has led to the need for a systematic and complete comparison of these methods. A method for conducting these comparisons is proposed and is applied to a set of currently-used stereotactic radiosurgical techniques. Three-dimensional treatment planning calculations are used to compare dose distributions for several different radiation types and irradiation geometries. Calculations were performed using charged particles (H, He, C, and Ne ions) and the irradiation geometry currently used at Lawrence Berkeley Laboratory. Photons in the Gamma Knife configuration and the Heidelberg Linac arc method are used. The 3-dimensional dose distributions were evaluated by means of dose-volume histograms and integral doses to the target volume and to normal brain. The effects of target volume, shape and location are studied. The charged particle dose distributions are more favorable than those of the photon methods. The differences between charged particles and photons increase with increasing target volume. The differences between different charged particle species are small, as are the effects of target shape and location. © 1990.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 13 条
  • [1] BARCIASALORIO JL, 1979, INSERM S, V12, P251
  • [2] DOSE VOLUME HISTOGRAMS IN TREATMENT PLANNING
    CHEN, GTY
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (06): : 1319 - 1320
  • [3] DESTRUCTION OF SMALL INTRACRANIAL TUMORS WITH CO-60 GAMMA-RADIATION - PHYSICAL AND TECHNICAL CONSIDERATIONS
    DAHLIN, H
    SARBY, B
    [J]. ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1975, 14 (03): : 209 - 227
  • [4] STEREOTACTIC HEAVY-ION BRAGG PEAK RADIOSURGERY FOR INTRA-CRANIAL VASCULAR DISORDERS - METHOD FOR TREATMENT OF DEEP ARTERIOVENOUS-MALFORMATIONS
    FABRIKANT, JI
    LYMAN, JT
    HOSOBUCHI, Y
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (678) : 479 - 490
  • [5] CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY
    HARTMANN, GH
    SCHLEGEL, W
    STURM, V
    KOBER, B
    PASTYR, O
    LORENZ, WJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06): : 1185 - 1192
  • [6] BRAGG-PEAK PROTON-BEAM THERAPY FOR ARTERIOVENOUS-MALFORMATIONS OF THE BRAIN
    KJELLBERG, RN
    HANAMURA, T
    DAVIS, KR
    LYONS, SL
    ADAMS, RD
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (05) : 269 - 274
  • [7] LAWRENCE JH, 1985, NEUROSURGERY, P1113
  • [8] STEREOTACTIC HEAVY-CHARGED-PARTICLE BRAGG PEAK RADIOSURGERY FOR THE TREATMENT OF INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS IN CHILDHOOD AND ADOLESCENCE
    LEVY, RP
    FABRIKANT, JI
    FRANKEL, KA
    PHILLIPS, MH
    LYMAN, JT
    [J]. NEUROSURGERY, 1989, 24 (06) : 841 - 852
  • [9] LUTZ W, 1988, INT J RADIAT ONCOL, V14, P387
  • [10] CHARGED-PARTICLE STEREOTACTIC RADIOSURGERY
    LYMAN, JT
    FABRIKANT, JI
    FRANKEL, KA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 10-1 (MAY) : 1107 - 1110