PRECISE GAMMA-RAY ENERGIES FOR CALIBRATION OF GE SEMICONDUCTOR SPECTROMETERS TO 3.5 MEV

被引:77
作者
GREENWOOD, RC
HELMER, RG
GEHRKE, RJ
机构
[1] Idaho National Engineering Laboratory, EG and G Idaho, Inc., Idaho Falls
来源
NUCLEAR INSTRUMENTS & METHODS | 1979年 / 159卷 / 2-3期
关键词
D O I
10.1016/0029-554X(79)90675-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Precise measurements with Ge(Li) detectors of γ-ray energies from several radionuclides that are useful as calibration standards in Ge semiconductor spectroscopy have been extended up to 3.5 MeV. The technique generally employed has utilized cascade-crossover combinations, with the energies of the cascade γ-rays being measured relative to other close-lying γ-rays whose energies were already known and the energy of the crossover γ-ray being computed from the cascade sum. All the energies are referenced, in a traceable manner, to the 198Au γ-ray energy value of 411.80441 keV recently measured at the National Bureau of Standards. Radionuclides for which γ-ray energies are reported include: 24Na, 48V, 56Co, 58Co, 60Co, 82Br, 84Rb, 88Y, 110mAg, 124Sb, 125Sn, 132Cs, 144Ce, 207Bi and 228Th. Typical uncertainties in the measured energies range from 5 to 15 eV between 1.3 and 3.5 MeV. © 1979.
引用
收藏
页码:465 / 482
页数:18
相关论文
共 12 条
  • [1] BORCHERT GL, 1976, Z NATURFORSCH A, V31, P387
  • [2] BORCHERT GL, 1976, ATOMIC MASSES FUNDAM, V5, P42
  • [3] Cohen E. R., 1973, Journal of Physical and Chemical Reference Data, V2, P663, DOI 10.1063/1.3253130
  • [4] PRECISE COMPARISON AND MEASUREMENT OF GAMMA-RAY ENERGIES WITH A GE(LI) DETECTOR .1. 50-420 KEV
    GREENWOOD, RC
    HELMER, RG
    GEHRKE, RJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 77 (01): : 141 - +
  • [5] RE-EVALUATION OF PRECISE GAMMA-RAY ENERGIES FOR CALIBRATION OF GE(LI) SPECTROMETERS
    HELMER, RG
    GREENWOOD, RC
    GEHRKE, RJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1978, 155 (1-2): : 189 - 201
  • [6] PRECISE COMPARISON AND MEASUREMENT OF GAMMA-RAY ENERGIES WITH A GE(LI) DETECTOR .2. 400-1300 KEV
    HELMER, RG
    GREENWOOD, RC
    GEHRKE, RJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (01): : 173 - +
  • [7] PEAK POSITION VARIATION WITH SOURCE GEOMETRY IN GE(LI) DETECTOR SPECTRA
    HELMER, RG
    GEHRKE, RJ
    GREENWOOD, RC
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1975, 123 (01): : 51 - 59
  • [8] HELMER RG, 1972, ANCR1043 AEC US REP
  • [9] PRECISION ENERGY MEASUREMENTS OF GAMMA-RAYS OCCURRING IN DECAY OF AG-110M
    KERN, J
    SCHWITZ, W
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1978, 151 (03): : 549 - 553
  • [10] REDETERMINATION OF AU-198 AND IR-192 GAMMA-RAY STANDARDS BETWEEN 0.1 AND 1.0 MEV
    KESSLER, EG
    DESLATTES, RD
    HENINS, A
    SAUDER, WC
    [J]. PHYSICAL REVIEW LETTERS, 1978, 40 (03) : 171 - 174