EXPERIMENTAL-DESIGN FOR THE RAPID SELECTION OF SEPARATION CONDITIONS FOR METHYL AND PROPYL PARAHYDROXYBENZOATE, PHENYLEPHRINE HYDROCHLORIDE AND CHLORPHENAMINE MALEATE BY ION-PAIR LIQUID-CHROMATOGRAPHY

被引:27
作者
DEBEER, JO [1 ]
VANDENBROUCKE, CV [1 ]
MASSART, DL [1 ]
机构
[1] FREE UNIV BRUSSELS, INST PHARMACEUT, B-1090 BRUSSELS, BELGIUM
关键词
ION-PAIR REVERSED-PHASE LIQUID CHROMATOGRAPHY; METHYL AND PROPYL PARAHYDROXYBENZOATE; PHENYLEPHRINE HYDROCHLORIDE; CHLORPHENAMINE MALEATE; FACE-CENTERED CENTRAL COMPOSITE DESIGN; REGRESSION MODELS; RESPONSE SURFACE PLOTS;
D O I
10.1016/0731-7085(94)00089-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methyl and propyl parahydroxybenzoate (MPHB, PPHB), phenylephrine hydrochloride (PE) and chlorphenamine maleate (CPM) are often combined as ingredients in cough-syrups. Due to distinct chemical structures, pK(a) values among other chemical properties are different. This may result in a particular chromatographic behaviour on ion-pair reversed-phase liquid chromatographic (LC) systems. A face-centred central composite design was applied to study the impact of four LC mobile phase parameters and parameter interactions on the retention of these four compounds. The mobile phase parameters studied were the concentration of methanol as organic modifier, the concentration of sodium dioctylsulphosuccinate (SDSS) as counter-ion, the concentration of dimethyloctylamine (DMOA) as competitive base and the pH. By means of the proposed design, mathematical regression models and response surface plots were calculated, which could predict the compounds' retention times with good statistical reliability. Adequate combination of the most relevant of these mobile phase parameters enabled complete chromatographic separations within short times of analysis.
引用
收藏
页码:1379 / 1396
页数:18
相关论文
共 21 条
[1]  
Box G.E.P., 1960, TECHNOMETRICS, V2, P455, DOI [DOI 10.2307/1266454, DOI 10.1080/00401706.1960.10489912]
[2]   ON THE EXPERIMENTAL ATTAINMENT OF OPTIMUM CONDITIONS [J].
BOX, GEP ;
WILSON, KB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1951, 13 (01) :1-45
[3]  
BOX GEP, 1973, STATISTICS EXPT INTR, P306
[4]  
BOX GEP, 1973, STATISTICS EXPT INTR, P503
[5]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF SULINDAC AND RELATED-COMPOUNDS USING A COMPUTER-SIMULATION [J].
COTTON, ML ;
DOWN, GRB .
JOURNAL OF CHROMATOGRAPHY, 1983, 259 (01) :17-36
[6]  
DEMING SN, 1987, EXPT DESIGN CHEMOMET, P135
[7]   METHOD DEVELOPMENT IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING RETENTION MAPPING AND EXPERIMENTAL-DESIGN TECHNIQUES [J].
GLAJCH, JL ;
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :51-63
[9]   UNIFORM SHELL DESIGNS FOR OPTIMIZATION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
HU, YZ ;
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :311-323
[10]   COMBINED EFFECTS OF PH AND SURFACE-ACTIVE-ION CONCENTRATION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
KONG, RC ;
SACHOK, B ;
DEMING, SN .
JOURNAL OF CHROMATOGRAPHY, 1980, 199 (OCT) :307-316