ADSORPTION OF FIBRINOGEN AND SOME OTHER PROTEINS FROM BLOOD-PLASMA AT A VARIETY OF SOLID-SURFACES

被引:41
作者
NIMERI, G
LASSEN, B
GOLANDER, CG
NILSSON, U
ELWING, H
机构
[1] LINKOPING UNIV, DEPT PHYS & MEASUREMENT TECHNOL, INTERFACE BIOL GRP, S-58183 LINKOPING, SWEDEN
[2] INST SURFACE CHEM, STOCKHOLM, SWEDEN
[3] PARMACIA OPHTALM, UPPSALA, SWEDEN
[4] ACAD HOSP, UPPSALA, SWEDEN
关键词
ELISA; PROTEIN ADSORPTION; POLYMERS; FIBRINOGEN;
D O I
10.1163/156856294X00527
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Enzyme linked immunosorbent assay (ELISA) was used for the estimation of protein adsorption from blood plasma at some model solid surfaces. The majority of those surfaces were made in the wells of microtiterplates of polystyrene commonly used for ELISA purposes. Three of the model surfaces were made by radio frequency plasma discharge polymerization (RFPD) of the microtiterplates of polystyrene. The monomers we used were diaminocyclohexane, hexamethylenedisiloxane, and acrylic acid. Other surfaces investigated were: unmodified polystyrene, oxidized polystyrene, hydrophilic silicon oxide, and methylized silicon oxide. Two substances, Tween and bovine serum albumin (BSA), for the prevention of unintended adsorption of ELISA conjugate were also tested and the BSA method was found to be superior for this kind of investigation. Human blood plasma at different dilutions was incubated in the surface-modified microtiterplates followed by incubation of rabbit antibodies against fibrinogen (FG), fibronectin (FN), human serum albumin (HSA), complement factor 3 (C-3), and immunoglobulin G (IgG). Visualization of bound antibodies was then made by standard ELISA procedure. At low blood plasma concentrations (plasma dil 1/1000), anti-IgG and anti-HSA were detected at high levels at the majority of surfaces. At high blood plasma concentration (plasma dil 1/10), anti-FG dominated at most surfaces. ELISA activity of FN and C-3 were low at most of the surfaces at both plasma concentrations. An 'optimum' plasma dilution for the detection of surface bound FG (the Vroman effect) was not found with the use of the ELISA on any of the surfaces except for the silicon oxide surface. This is in contrast to findings by others who had used isotope-labelled fibronogen diluted in plasma. However, 'false' Vroman effects occured if nonionic surfactant was used for the prevention of unspecific binding in the ELISA.
引用
收藏
页码:573 / 583
页数:11
相关论文
共 30 条
[1]   STUDY ON THE PREVENTION OF SURFACE-INDUCED PLATELET ACTIVATION BY ALBUMIN COATING [J].
AMIJI, M ;
PARK, H ;
PARK, K .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1992, 3 (05) :375-388
[2]  
BALE MD, 1989, BLOOD, V74, P2698
[3]  
BATTJES KP, 1992, SILANES OTHER COUPLI, P199
[4]   TRANSIENT ADSORPTION OF FIBRINOGEN ON FOREIGN SURFACES - SIMILAR BEHAVIOR IN PLASMA AND WHOLE-BLOOD [J].
BRASH, JL ;
TENHOVE, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (02) :157-169
[5]  
BRASH JL, 1984, THROMB HAEMOSTASIS, V51, P326
[6]  
BRASH JL, 1988, BLOOD, V71, P932
[7]  
BURNS NJ, UNPUB
[8]  
CARBALLO J, 1991, MED MICROBIOL IMMUN, V180, P149
[9]   STRUCTURE AND SURFACE-PROPERTIES OF PLASMA POLYMERIZED ACRYLIC-ACID LAYERS [J].
CHO, DL ;
CLAESSON, PM ;
GOLANDER, CG ;
JOHANSSON, K .
JOURNAL OF APPLIED POLYMER SCIENCE, 1990, 41 (7-8) :1373-1390
[10]   COMPETITION BETWEEN ADSORBED FIBRINOGEN AND HIGH-MOLECULAR-WEIGHT KININOGEN ON SOLID-SURFACES INCUBATED IN HUMAN-PLASMA (THE VROMAN EFFECT) - INFLUENCE OF SOLID-SURFACE WETTABILITY [J].
ELWING, H ;
ASKENDAL, A ;
LUNDSTROM, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (08) :1023-1028