MEASUREMENT OF SCATTER FRACTIONS IN ERECT POSTEROANTERIOR AND LATERAL CHEST RADIOGRAPHY

被引:13
作者
JORDAN, LK [1 ]
FLOYD, CE [1 ]
LO, JY [1 ]
RAVIN, CE [1 ]
机构
[1] DUKE UNIV, MED CTR,DEPT RADIOL,DIV THORAC IMAGING RES, BOX 3949, DURHAM, NC 27710 USA
关键词
RADIATIONS; MEASUREMENT; THORAX; RADIOGRAPHY;
D O I
10.1148/radiology.188.1.8511301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Scatter fractions (SFs) measured in patients undergoing erect posteroanterior (PA) and lateral chest radiography with a 12:1 antiscatter grid are reported. Modifications to the posterior beam-stop (PBS) technique allowed measurement of scatter in these patients, without altering the diagnostic image and without additional radiation exposure. The SF measurements are reported by anatomic location on 42 clinical chest images. Average SF values ranged from 0.27 to 0.90 on lateral radiographs and from 0.27 to 0.68 on PA radiographs. Scatter measurements with the 12:1 grid were found to be greater than estimates from previous PA chest phantom experiments. To the authors' knowledge, they were the first to measure radiation scatter with the PBS technique in patients undergoing PA and lateral chest radiography with the antiscatter grid.
引用
收藏
页码:215 / 218
页数:4
相关论文
共 17 条
[1]
SCANNING MULTIPLE SLIT ASSEMBLY - PRACTICAL AND EFFICIENT DEVICE TO REDUCE SCATTER [J].
BARNES, GT ;
BREZOVICH, IA ;
WITTEN, DM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1977, 129 (03) :497-501
[3]
MEASUREMENT OF SCATTER FRACTIONS IN CLINICAL BEDSIDE RADIOGRAPHY [J].
FLOYD, CE ;
BAKER, JA ;
LO, JY ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (03) :857-861
[4]
QUANTITATIVE RADIOGRAPHIC IMAGING USING A PHOTOSTIMULABLE PHOSPHOR SYSTEM [J].
FLOYD, CE ;
CHOTAS, HG ;
DOBBINS, JT ;
RAVIN, CE .
MEDICAL PHYSICS, 1990, 17 (03) :454-459
[5]
POSTERIOR BEAM-STOP METHOD FOR SCATTER FRACTION MEASUREMENT IN DIGITAL RADIOGRAPHY [J].
FLOYD, CE ;
BAKER, JA ;
LO, JY ;
RAVIN, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :119-123
[6]
SCATTER COMPENSATION IN DIGITAL CHEST RADIOGRAPHY USING FOURIER DECONVOLUTION [J].
FLOYD, CE ;
BEATTY, PT ;
RAVIN, CE .
INVESTIGATIVE RADIOLOGY, 1989, 24 (01) :30-33
[7]
SCATTER ESTIMATION FOR A DIGITAL RADIOGRAPHIC SYSTEM USING CONVOLUTION FILTERING [J].
LOVE, LA ;
KRUGER, RA .
MEDICAL PHYSICS, 1987, 14 (02) :178-185
[8]
SCATTERED RADIATION IN CHEST RADIOGRAPHY [J].
NIKLASON, LT ;
SORENSON, JA ;
NELSON, JA .
MEDICAL PHYSICS, 1981, 8 (05) :677-681
[9]
SCATTER REJECTION BY ELECTRONIC COLLIMATION [J].
PLENKOVICH, D ;
SORENSON, JA ;
KRUGER, RA .
MEDICAL PHYSICS, 1986, 13 (02) :158-163
[10]
A SCANNING SYSTEM FOR CHEST RADIOGRAPHY WITH REGIONAL EXPOSURE CONTROL - PRACTICAL IMPLEMENTATION [J].
PLEWES, DB ;
VOGELSTEIN, E .
MEDICAL PHYSICS, 1983, 10 (05) :655-663