HEMOPTYSIS FOLLOWING INSERTION OF A SWAN-GANZ CATHETER

被引:19
作者
KRANTZ, EM [1 ]
VILJOEN, JF [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,LOS ANGELES,CA 90024
关键词
D O I
10.1093/bja/51.5.457
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Haemoptysis occurred in a patient in whom a Swan-Ganz catheter was inserted for the induction of anaesthesia for hemicolectomy. It is suggested that acute pulmonary hypertension, superimposed on existing chronic pulmonary hypertension associated with mitral stenosis, was an important aetiological factor in the haemoptysis. © 1979 Macmillan Journals Ltd.
引用
收藏
页码:457 / 459
页数:3
相关论文
共 7 条
[1]  
CHUN GMH, 1971, NEW ENGL J MED, V284, P1041
[2]   FILLING PRESSURES IN RIGHT AND LEFT SIDES OF HEART IN ACUTE MYOCARDIAL INFARCTION - REAPPRAISAL OF CENTRAL-VENOUS-PRESSURE MONITORING [J].
FORRESTE.JS ;
DIAMOND, G ;
MCHUGH, TJ ;
SWAN, HJC .
NEW ENGLAND JOURNAL OF MEDICINE, 1971, 285 (04) :190-&
[3]  
GERMAN JC, 1973, ARCH SURG-CHICAGO, V106, P788
[4]   FATAL PULMONARY HEMORRHAGE COMPLICATING USE OF A FLOW-DIRECTED BALLOON-TIPPED CATHETER IN A PATIENT RECEIVING ANTICOAGULANT THERAPY [J].
GOLDEN, MS ;
PINDER, T ;
ANDERSON, WT ;
CHEITLIN, MD .
AMERICAN JOURNAL OF CARDIOLOGY, 1973, 32 (06) :865-867
[5]   HEMOPTYSIS WITH FLOW-DIRECTED CARDIAC CATHETERIZATION [J].
LAPIN, ES ;
MURRAY, JA .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 220 (09) :1246-&
[6]  
PAGE DW, 1974, NEW ENGL J MED, V291, P260
[7]   CATHETERIZATION OF HEART IN MAN WITH USE OF FLOW-DIRECTED BALLOON-TIPPED CATHETER [J].
SWAN, HJC ;
GANZ, W ;
FORRESTER, J ;
MARCUS, H ;
DIAMOND, G ;
CHONETTE, D .
NEW ENGLAND JOURNAL OF MEDICINE, 1970, 283 (09) :447-+