2 DIMENSIONAL ECHOCARDIOGRAPHIC ASSESSMENT OF PATIENTS WITH BIO-PROSTHETIC VALVES

被引:62
作者
SCHAPIRA, JN
MARTIN, RP
FOWLES, RE
RAKOWSKI, H
STINSON, EB
FRENCH, JW
SHUMWAY, NE
POPP, RL
机构
[1] STANFORD UNIV,SCH MED,DEPT CARDIOVASC SURG,DIV CARDIOL,STANFORD,CA 94305
[2] STANFORD UNIV,SCH MED,DIV PEDIAT,STANFORD,CA 94305
基金
美国国家卫生研究院;
关键词
D O I
10.1016/0002-9149(79)90007-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The clinical utility of two dimensional echocardiography in assessing bioprosthetic and left ventricular function was studied in 40 consecutive patients 1 week to 60 months after valve replacement surgery. These patients were referred to obtain normal baseline studies as well as to evaluate complications: suspected endocarditis, embolic phenomena and congestive heart failure of unknown cause. Independent M mode echo-cardiograms were also obtained in each patient. Confirmation of ultrasonic studies was by cardiac catheterization with angiography, surgery and pathologic study in 10 patients; cardiac catheterization with angiography alone in 7 patients; surgery and pathologic study in 3 patients; autopsy in 3 patients; blood cultures to confirm or exclude endocarditis in 10 patients; and confirmation on clinical grounds in 7 patients. Technically adequate two dimensional studies were recorded in 39 of 40 subjects. Two dimensional echocardiography accurately assessed 15 of 16 patients with an abnormal bioprosthetic valve and a normal left ventricle (1 of 16 patients had a false positive two dimensional echocardiogram); 8 of 8 patients suspected to have prosthetic valve or left ventricular dysfunction but who were normal; 7 of 7 patients with a normal prosthesis and an abnormal left ventricle; the one patient with an abnormal valve and left ventricle; and 7 of 7 clinically normal patients who were referred for baseline studies. In summary, the two-dimensional echocardiogram demonstrated a 97 percent diagnostic accuracy rate which was significantly greater than the 67 percent (P < 0.001) for M mode echocardiography in the same group of patients. It is concluded that two dimensional echocardiography has excellent diagnostic accuracy in assessing bioprosthetic and left ventricular function and is superior to M mode echocardiography in evaluating patients after such valve replacement. © 1979.
引用
收藏
页码:510 / 519
页数:10
相关论文
共 18 条
[1]  
ANDERSON WA, 1977, ULTRASOUND MEDICIN B, V3, P1547
[2]   ECHOCARDIOGRAM OF PORCINE AORTIC BIOPROSTHESIS IN MITRAL POSITION [J].
BLOCH, WN ;
FELNER, JM ;
WICKLIFFE, C ;
SYMBAS, PN ;
SCHLANT, RC .
AMERICAN JOURNAL OF CARDIOLOGY, 1976, 38 (03) :293-298
[3]   ECHOCARDIOGRAM OF PORCINE AORTIC BIOPROSTHESIS IN AORTIC POSITION [J].
BLOCH, WN ;
FELNER, JM ;
SCHLANT, RC ;
SYMBAS, PN ;
JONES, EL .
CHEST, 1977, 72 (05) :640-646
[4]   INVITRO AND INVIVO EVALUATION OF PORCINE BIOPROSTHESES BY CROSS-SECTIONAL ECHOCARDIOGRAPHY [J].
BOMMER, W ;
YOON, D ;
GREHL, TM ;
MASON, DT ;
NEUMANN, A ;
DEMARIA, AN .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (02) :405-405
[5]   THROMBOEMBOLISM IN MITRAL PORCINE VALVE RECIPIENTS [J].
EDMISTON, WA ;
HARRISON, EC ;
DUICK, GF ;
PARNASSUS, W ;
LAU, FYK .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (03) :508-511
[6]  
HANNAH H, 1976, CIRCULATION, V54, P27
[7]   ECHOCARDIOGRAPHIC EVALUATION OF STENT MOUNTED AORTIC BIOPROSTHETIC VALVE IN MITRAL POSITION - INVITRO AND INVIVO STUDIES [J].
HOROWITZ, MS ;
TECKLENBERG, PL ;
GOODMAN, DJ ;
HARRISON, DC ;
POPP, RL .
CIRCULATION, 1976, 54 (01) :91-96
[8]  
HOROWITZ MS, 1976, J THORAC CARDIOV SUR, V71, P450
[9]   CARDIAC IMAGING USING A PHASED-ARRAY ULTRASOUND SYSTEM .2. CLINICAL TECHNIQUE AND APPLICATION [J].
KISSLO, J ;
VONRAMM, OT ;
THURSTONE, FL .
CIRCULATION, 1976, 53 (02) :262-267
[10]   VALVE-REPLACEMENT WITH STARR-EDWARDS AND HANCOCK PROSTHESES - COMPARATIVE ANALYSIS OF LATE MORBIDITY AND MORTALITY [J].
OYER, PE ;
STINSON, EB ;
GRIEPP, RB ;
SHUMWAY, NE .
ANNALS OF SURGERY, 1977, 186 (03) :301-309