A MEDIATED AMPEROMETRIC ENZYME ELECTRODE USING TETRATHIAFULVALENE AND L-GLUTAMATE OXIDASE FOR THE DETERMINATION OF L-GLUTAMIC ACID

被引:36
作者
ALMEIDA, NF [1 ]
MULCHANDANI, AK [1 ]
机构
[1] UNIV CALIF RIVERSIDE,DEPT CHEM ENGN,RIVERSIDE,CA 92521
基金
美国国家科学基金会;
关键词
AMPEROMETRY; BIOSENSORS; CARBON PASTE; ELECTROPOLYMERIZATION; ENZYME ELECTRODES; GLUTAMIC ACID; GLUTAMATE OXIDASE; TETRATHIAFULVALENE;
D O I
10.1016/0003-2670(93)80221-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mediated amperometric sensor for measuring L-glutamate is described. The sensor is based on a carbon paste electrode containing the electron transfer mediator tetrathiafulvalene (TTF), and the enzyme L-glutamate oxidase immobilized on the electrode surface. The enzyme is crosslinked with glutaraldehyde and the matrix held on the electrode surface using an electrochemically deposited polymer. TTF is shown to efficiently reoxidize the reduced flavin adenine dinucleotide centers of glutamate oxidase, permitting operation of the sensor at low applied potentials. The electrode, when operated at +0.15 V (vs. Ag/AgCl), responded linearly to L-glutamate concentrations up to 0.8 mM, the lower detection limit being 2.6 muM, with a response time of 2 min. The sensor was used for the determination of L-glutamate in food samples, with excellent correlations achieved when compared to results obtained by enzymatic analysis using glutamate dehydrogenase. The enzyme electrode exhibits excellent reproducibility and stability, retaining more than 90% of its original activity over a period of 3 weeks.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 29 条
  • [1] ENZYME ELECTRODE FOR DETERMINATION OF L-GLUTAMIC ACID
    AHN, BK
    WOLFSON, SK
    YAO, SJ
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1975, 2 (02): : 142 - 153
  • [2] CARDOSI MF, 1990, BIOSENSORS FUNDAMENT, P257
  • [3] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [4] MONITORING GLUTAMINE IN MAMMALIAN-CELL CULTURES USING AN AMPEROMETRIC BIOSENSOR
    CATTANEO, MV
    LUONG, JHT
    MERCILLE, S
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (05) : 329 - 334
  • [5] CHEN CY, 1991, ANAL CHIM ACTA, V243, P9
  • [6] IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS
    FOULDS, NC
    LOWE, CR
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (22) : 2473 - 2478
  • [7] ELECTROPOLYMERIZED FILMS TO PREVENT INTERFERENCES AND ELECTRODE FOULING IN BIOSENSORS
    GEISE, RJ
    ADAMS, JM
    BARONE, NJ
    YACYNYCH, AM
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) : 151 - 160
  • [8] A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER
    GORTON, L
    KARAN, HI
    HALE, PD
    INAGAKI, T
    OKAMOTO, Y
    SKOTHEIM, TA
    [J]. ANALYTICA CHIMICA ACTA, 1990, 228 (01) : 23 - 30
  • [9] CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS
    GREGG, BA
    HELLER, A
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (03) : 258 - 263
  • [10] CARBON PASTE-TETRATHIAFULVALENE AMPEROMETRIC ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE IN FLOWING SYSTEMS
    GUNASINGHAM, H
    TAN, CH
    [J]. ANALYST, 1990, 115 (01) : 35 - 39