DOES INTRACORONARY INFUSION OF FLUOSOL-DA 20-PERCENT PREVENT LEFT-VENTRICULAR DIASTOLIC DYSFUNCTION DURING CORONARY BALLOON ANGIOPLASTY

被引:17
作者
BELL, MR
NISHIMURA, RA
HOLMES, DR
BAILEY, KR
SCHWARTZ, RS
VLIETSTRA, RE
机构
[1] MAYO CLIN & MAYO FDN, DIV CARDIOVASC DIS & INTERNAL MED, 200 1ST ST SW, ROCHESTER, MN 55905 USA
[2] MAYO CLIN & MAYO FDN, DIV HLTH SCI RES, BIOSTAT SECT, ROCHESTER, MN 55905 USA
关键词
D O I
10.1016/S0735-1097(10)80349-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Distal intracoronary infusion of the perfluorochemical Fluosol-DA 20% has been shown to prevent systolic dysfunction during coronary artery balloon occlusion in coronary angioplasty. To assess its effect on global diastolic dysfunction, a randomized, single-blind, crossover protocol comparing intracoronary infusion of Fluosol or no infusion (control) was performed during 60 s balloon inflations in 10 patients (mean age 67 years) undergoing coronary angioplasty. Assessment of global systolic and diastolic function was obtained with high fidelity micromanometer measurements of left ventricular pressure. Eighteen pairs of balloon inflations (Fluosol versus control) were analyzed. Patients reported significantly less severe chest pain during inflations accompanied by Fluosol compared with control. However, during coronary balloon occlusion, no significant differences in the changes from baseline values were observed between Fluosol and control with regard to ventricular relaxation, including the time constant of early ventricular relaxation (tau) and maximal rate of fall in left ventricular pressure (maximal negative dP/dt). No differences between Fluosol and control were observed in terms of the increase in end-diastolic pressure or minimal distolic pressure during balloon inflation. Mean systolic pressure decrease from baseline values was greater during control than during Fluosol inflations (−9.0 ± 3.3 mm Hg, p = 0.013), but no significant difference was observed in the change in maximal rate of rise in left ventricular pressure (maximal positive dP/dt). These results suggest that Fluosol does not preserve global left ventricular diastolic function during coronary balloon occlusion, possibly because of its limited oxygen delivery capability relative to arterial blood. © 1990, American College of Cardiology Foundation. All rights reserved.
引用
收藏
页码:959 / 966
页数:8
相关论文
共 26 条
[1]   DISTAL CORONARY-ARTERY PERFUSION DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
ANDERSON, HV ;
LEIMGRUBER, PP ;
ROUBIN, GS ;
NELSON, DL ;
GRUENTZIG, AR .
AMERICAN HEART JOURNAL, 1985, 110 (04) :720-726
[2]   SIMULTANEOUS ASSESSMENT OF LEFT-VENTRICULAR SYSTOLIC AND DIASTOLIC DYSFUNCTION DURING PACING-INDUCED ISCHEMIA [J].
AROESTY, JM ;
MCKAY, RG ;
HELLER, GV ;
ROYAL, HD ;
ALS, AV ;
GROSSMAN, W .
CIRCULATION, 1985, 71 (05) :889-900
[3]   LEFT-VENTRICULAR SYSTOLIC AND DIASTOLIC FUNCTION DURING ACUTE CORONARY-ARTERY BALLOON OCCLUSION IN HUMANS [J].
BERTRAND, ME ;
LABLANCHE, JM ;
FOURRIER, JL ;
TRAISNEL, G ;
MIRSKY, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :341-347
[4]  
BING RJ, 1951, B NEW YORK ACAD MED, V27, P407
[5]   IMPAIRED LEFT-VENTRICULAR DIASTOLIC FILLING IN PATIENTS WITH CORONARY-ARTERY DISEASE - ASSESSMENT WITH RADIONUCLIDE ANGIOGRAPHY [J].
BONOW, RO ;
BACHARACH, SL ;
GREEN, MV ;
KENT, KM ;
ROSING, DR ;
LIPSON, LC ;
LEON, MB ;
EPSTEIN, SE .
CIRCULATION, 1981, 64 (02) :315-323
[6]  
BOWMAN L, 1988, Journal of the American College of Cardiology, V11, p133A
[7]   COMBINED INFLUENCE OF VENTRICULAR LOADING AND RELAXATION ON THE TRANSMITRAL FLOW VELOCITY PROFILE IN DOGS MEASURED BY DOPPLER ECHOCARDIOGRAPHY [J].
CHOONG, CY ;
ABASCAL, VM ;
THOMAS, JD ;
GUERRERO, JL ;
MCGLEW, S ;
WEYMAN, AE .
CIRCULATION, 1988, 78 (03) :672-683
[8]   INADEQUATE SUBENDOCARDIAL OXYGEN DELIVERY DURING PERFLUOROCARBON PERFUSION IN A CANINE MODEL OF ISCHEMIA [J].
CHRISTENSEN, CW ;
REEVES, WC ;
LASSAR, TA ;
SCHMIDT, DH .
AMERICAN HEART JOURNAL, 1988, 115 (01) :30-37
[9]   PREVENTION OF ISCHEMIA DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY BY TRANSCATHETER INFUSION OF OXYGENATED FLUOSOL DA 20-PERCENT [J].
CLEMAN, M ;
JAFFEE, CC ;
WOHLGELERNTER, D .
CIRCULATION, 1986, 74 (03) :555-562
[10]   THE TRANSMITRAL PRESSURE-FLOW VELOCITY RELATION - EFFECT OF ABRUPT PRELOAD REDUCTION [J].
COURTOIS, M ;
VERED, Z ;
BARZILAI, B ;
RICCIOTTI, NA ;
PEREZ, JE ;
LUDBROOK, PA .
CIRCULATION, 1988, 78 (06) :1459-1468