OPTIMAL TIME-WINDOW DURATION FOR COMPUTING TIME FREQUENCY REPRESENTATION OF NORMAL PHONOCARDIOGRAMS IN DOGS

被引:13
作者
JAMOUS, G
DURAND, LG
LANGLOIS, YE
LANTHIER, T
PIBAROT, P
CARIOTO, S
机构
[1] HOP HOTEL DIEU,MONTREAL HOSP,MONTREAL H2W 1T8,QUEBEC,CANADA
[2] UNIV MONTREAL,FAC VET MED,DEPT MED,ST HYACINTHE J2S 7C6,QUEBEC,CANADA
关键词
COHERENCE FUNCTION; PHONOCARDIOGRAM; SPECTROGRAPHIC ANALYSIS; TIME-WINDOW DURATION;
D O I
10.1007/BF02457829
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The optimal duration of the time-window used to compute the time-frequency representation (spectrogram) of the phonocardiogram was studied in four dogs by using intracardiac and thoracic measurements of the PCG. The power and cross-spectrograms of the intracardiac and thoracic PCGs were computed using a fast Fourier transform algorithm and a sine-cosine window with 10 per cent decaying functions. A coherence spectrogram was also computed for each dog to study the linear relationship between the two signals and determine the optimal time-window duration. Results show that the optimal range of the time-window duration is between 16 and 32 ms. A time-window shorter than 16 ms spreads out low-frequency components into the higher frequencies and generates a spectrographic representation with poor frequency resolution (greater-than-or-equal-to 62.5 Hz). A window larger than 32 ms increases the frequency resolution but smears the spectrographic representation of the signal in the time domain and thus cannot correctly reflect the time-varying properties of the signal. In both cases, the amplitude of the coherence function computed between the left ventricular and the thoracic phonocardiograms is overestimated.
引用
收藏
页码:503 / 508
页数:6
相关论文
共 17 条
[1]  
AIGNER VA, 1977, FORTSCHR MED, V95, P2162
[2]  
AIGNER VA, 1973, Z KARDIOL, V62, P1105
[3]   AN ALGORITHM FOR MACHINE CALCULATION OF COMPLEX FOURIER SERIES [J].
COOLEY, JW ;
TUKEY, JW .
MATHEMATICS OF COMPUTATION, 1965, 19 (90) :297-&
[4]   SPECTRAL-ANALYSIS AND ACOUSTIC TRANSMISSION OF MITRAL AND AORTIC-VALVE CLOSURE SOUNDS IN DOGS .1. MODELING THE HEART THORAX ACOUSTIC SYSTEM [J].
DURAND, LG ;
LANGLOIS, YE ;
LANTHIER, T ;
CHIARELLA, R ;
COPPENS, P ;
CARIOTO, S ;
BERTRANDBRADLEY, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (04) :269-277
[5]   SPECTRAL-ANALYSIS AND ACOUSTIC TRANSMISSION OF MITRAL AND AORTIC-VALVE CLOSURE SOUNDS IN DOGS .4. EFFECT OF MODULATING CARDIAC INOTROPY [J].
DURAND, LG ;
LANGLOIS, YE ;
LANTHIER, T ;
CHIARELLA, R ;
COPPENS, P ;
CARIOTO, S ;
BERTRANDBRADLEY, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (05) :439-445
[6]   SPECTRAL-ANALYSIS AND ACOUSTIC TRANSMISSION OF MITRAL AND AORTIC-VALVE CLOSURE SOUNDS IN DOGS .3. EFFECTS OF ALTERING HEART-RATE AND P-R INTERVAL [J].
DURAND, LG ;
LANGLOIS, YE ;
LANTHIER, T ;
CHIARELLA, R ;
COPPENS, P ;
CARIOTO, S ;
BERTRANDBRADLEY, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (05) :431-438
[7]   SPECTRAL-ANALYSIS AND ACOUSTIC TRANSMISSION OF MITRAL AND AORTIC-VALVE CLOSURE SOUNDS IN DOGS .2. EFFECTS OF NEUROMUSCULAR BLOCKADE, STERNOTOMY AND PACEMAKER CONTROL, AND A 2-WEEK RECOVERY PERIOD [J].
DURAND, LG ;
LANGLOIS, YE ;
LANTHIER, T ;
CHIARELLA, R ;
COPPENS, P ;
CARIOTO, S ;
BERTRANDBRADLEY, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (04) :278-286
[8]   MODELING OF THE TRANSFER-FUNCTION OF THE HEART THORAX ACOUSTIC SYSTEM IN DOGS [J].
DURAND, LG ;
GENEST, J ;
GUARDO, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (08) :592-601
[9]  
DURAND LG, 1982, APPLICATIONS COMPUTE, P29
[10]  
DURAND LG, 1986, INNOV TECH BIOL MED, V7, P458