THE RISK OF SMALL ST-JUDE AORTIC-VALVE PROSTHESES

被引:72
作者
KRATZ, JM
SADE, RM
CRAWFORD, FA
CRUMBLEY, AJ
STROUD, MR
机构
[1] Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
关键词
D O I
10.1016/0003-4975(94)91339-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We reviewed our 12-year experience with 254 adult patients who had St. Jude valves in the aortic position and used multivariate analysis to examine risk factors possibly affecting long-term morbidity and mortality. Nineteen-millimeter or 21-mm valves were implanted in 115 patients. Poor preoperative congestive heart failure status was associated with persistent congestive heart failure on late follow-up. Preoperative congestive heart failure and coronary artery disease were the only predictors of overall late death. Late deaths associated with heart failure and late sudden deaths were examined separately. Preoperative degree of heart failure was the only predictor of late death with associated heart failure. The implantation of a 19- or 21-mm valve in patients with a body surface area greater than 1.9 m(2) somewhat increased the risk of late sudden death. In patients with a body surface area greater than 1.9 m(2) and with a 19-mm or 21-mm annulus, consideration should be given to using a high-performance St. Jude valve or performing an annulus-enlarging procedure if this can be done with negligible morbidity.
引用
收藏
页码:1114 / 1119
页数:6
相关论文
共 24 条
[1]  
Afifi A.A., 1984, COMPUTER AIDED MULTI
[2]   10 YEARS EXPERIENCE WITH THE ST JUDE MEDICAL VALVE PROSTHESIS [J].
AROM, KV ;
NICOLOFF, DM ;
KERSTEN, TE ;
NORTHRUP, WF ;
LINDSAY, WG ;
EMERY, RW .
ANNALS OF THORACIC SURGERY, 1989, 47 (06) :831-837
[3]   JUDE,ST MEDICAL PROSTHESIS - ANOTHER 10-YEAR FOLLOW-UP REPORT [J].
AROM, KV .
ANNALS OF THORACIC SURGERY, 1993, 56 (03) :403-404
[4]   SIGNIFICANCE OF POSITION AND OPENING ANGLE OF BJORK-SHILEY TILTING DISC VALVE IN MITRAL SURGERY [J].
BJORK, VO ;
BOOK, K ;
HOLMGREN, A .
SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1973, 7 (03) :187-201
[5]  
BLANK RH, 1976, ANN THORAC SURG, V22, P356, DOI 10.1016/S0003-4975(10)64967-3
[6]   CHANGES IN CARDIAC OUTPUT WITH AGE [J].
BRANDFONBRENER, M ;
LANDOWNE, M ;
SHOCK, NW .
CIRCULATION, 1955, 12 (04) :557-566
[7]   AORTIC-VALVE REPLACEMENT WITH HANCOCK PORCINE XENOGRAFT [J].
COHN, LH ;
SANDERS, JH ;
COLLINS, JJ .
ANNALS OF THORACIC SURGERY, 1976, 22 (03) :221-227
[8]  
COX DR, 1972, J R STAT SOC B, V34, P187
[9]  
CZER LSC, 1990, J THORAC CARDIOV SUR, V100, P44
[10]   AORTIC-VALVE REPLACEMENT IN ADULT PATIENTS WITH SMALL AORTIC ANNULI [J].
DAVID, TE ;
UDEN, DE .
ANNALS OF THORACIC SURGERY, 1983, 36 (05) :577-583