SUPERFICIAL MASSES WITH COLOR FLOW DOPPLER IMAGING

被引:27
作者
MITCHELL, DG [1 ]
MERTON, DA [1 ]
LIU, JB [1 ]
GOLDBERG, BB [1 ]
机构
[1] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,PHILADELPHIA,PA 19107
关键词
COLOR DOPPLER IMAGING; SUPERFICIAL MASSES; PSEUDOANEURYSMS; PERIPHERAL VESSELS; FLUID COLLECTIONS;
D O I
10.1002/jcu.1870190906
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Color Doppler imaging findings and spectral waveforms were reviewed for 21 superficial masses in which color Doppler imaging revealed flow. This series included 5 benign hyperplastic lymph nodes, 5 malignant masses, 2 staphylococcus abscesses, and 9 pseudoaneurysms. Benign hyperplastic nodes had a vascular pattern consisting of prominent central flow with a branching radial pattern, reflecting the morphology of lymph nodes. One metastasis from melanoma demonstrated abundant peripheral flow and central avascularity, while the other 4 malignant masses and the 2 abscesses had sparse internal flow. All pseudoaneurysms had a to-and-fro imaging and spectral pattern (into the mass during systole, out during diastole), and/or a swirling pattern on real-time images (8 of 9 each). Doppler spectral analysis revealed continuous forward flow during diastole for all other masses and abscesses. Waveforms appeared similar for benign and malignant masses, and for abscesses. Conventional image-directed Doppler examinations performed prior to color Doppler studies failed to reveal flow in 2 partially thrombosed pseudoaneurysms, 1 malignant mass, and 1 abscess. Benign hyperplastic nodes, malignant masses, and pseudoaneurysms had distinctive color Doppler image appearances in this series, although demonstration of flow within a mass does not eliminate the possibility of abscess. Proper use of color and spectral Doppler analysis of superficial masses involves more than mere detection or exclusion of flow.
引用
收藏
页码:555 / 560
页数:6
相关论文
共 17 条
[1]   THE TO-AND-FRO SIGN - DUPLEX DOPPLER EVIDENCE OF FEMORAL-ARTERY PSEUDOANEURYSM [J].
ABUYOUSEF, MM ;
WIESE, JA ;
SHAMMA, AR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (03) :632-634
[2]   PERIPHERAL PSEUDOANEURYSMS - EVALUATION WITH DUPLEX US [J].
COUGHLIN, BF ;
PAUSHTER, DM .
RADIOLOGY, 1988, 168 (02) :339-342
[3]   THE DISTINCTION BETWEEN FEMORAL-ARTERY PSEUDOANEURYSMS AND OTHER CAUSES OF GROIN MASSES - VALUE OF DUPLEX DOPPLER SONOGRAPHY [J].
HELVIE, MA ;
RUBIN, JM ;
SILVER, TM ;
KRESOWIK, TF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :1177-1180
[4]  
HELVIE MA, 1989, J ULTRAS MED, V8, P21
[5]   IATROGENIC FEMORAL ARTERIOVENOUS-FISTULA - DIAGNOSIS WITH COLOR DOPPLER IMAGING [J].
IGIDBASHIAN, VN ;
MITCHELL, DG ;
MIDDLETON, WD ;
SCHWARTZ, RA ;
GOLDBERG, BB .
RADIOLOGY, 1989, 170 (03) :749-752
[6]   SMALL ARTERIES IN PERIPHERAL LYMPH-NODES - A SPECIFIC ULTRASOUND SIGN OF LYMPHOMATOUS INVOLVEMENT [J].
MAJER, MC ;
HESS, CF ;
KOLBEL, G ;
SCHMIEDL, U .
RADIOLOGY, 1988, 168 (01) :241-243
[7]   FEMORAL-ARTERY PSEUDOANEURYSM - DIAGNOSIS WITH CONVENTIONAL DUPLEX AND COLOR DOPPLER US [J].
MITCHELL, DG ;
NEEDLEMAN, L ;
BEZZI, M ;
GOLDBERG, BB ;
KURTZ, AB ;
PENNELL, RG ;
RIFKIN, MD ;
VILARO, M ;
BALTAROWICH, OH .
RADIOLOGY, 1987, 165 (03) :687-690
[8]  
MORSE SI, 1986, INFECT DIS, P236
[9]   INGUINAL LYMPHADENOPATHY SIMULATING A FALSE ANEURYSM ON COLOR-FLOW DOPPLER SONOGRAPHY [J].
MORTON, MJ ;
CHARBONEAU, JW ;
BANKS, PM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (01) :115-116
[10]  
PICK TP, 1978, GRAYS ANATOMY, P1133