6-MONTH QUANTITATIVE ANGIOGRAPHIC FOLLOW-UP OF LESS-THAN-50-PERCENT DIAMETER STENOSES DILATED DURING MULTILESION PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY

被引:8
作者
HAMON, M
BAUTERS, C
MCFADDEN, EP
LABLANCHE, JM
BERTRAND, ME
机构
[1] Service de Cardiologie B et Hémodynamique, Hôpital Cardiologique, 59037 Lille Cedex, Boulevard du Professeur J Leclercq
关键词
D O I
10.1016/0002-9149(93)90652-S
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In patients who undergo percutaneous transluminal coronary angioplasty (PTCA), nonsignificant (<50% reduction in lumen diameter) stenoses frequently coexist with more severe target lesions. No study has examined the quantitative angiographic outcome when these narrowings are treated by PTCA. This study was designed to determine how often lesions with <50% luminal diameter narrowing, assessed by quantitative coronary angiography, were dilated during consecutive multivessel PTCA procedures in our institution and to determine the angiographic outcome of these dilations at 6 months. © 1993.
引用
收藏
页码:1226 / 1229
页数:4
相关论文
共 10 条
[1]   CLINICAL CHARACTERISTICS AND ANGIOGRAPHIC FOLLOW-UP OF PATIENTS UNDERGOING EARLY OR LATE REPEAT DILATION FOR A 1ST RESTENOSIS [J].
BAUTERS, C ;
LABLANCHE, JM ;
MCFADDEN, EP ;
LEROY, F ;
BERTRAND, ME .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) :845-848
[2]   RESTENOSIS AFTER CORONARY ANGIOPLASTY - THE PARADOX OF INCREASED LUMEN DIAMETER AND RESTENOSIS [J].
BEATT, KJ ;
SERRUYS, PW ;
LUIJTEN, HE ;
RENSING, BJ ;
SURYAPRANATA, H ;
DEFEYTER, P ;
VANDENBRAND, M ;
LAARMAN, GJ ;
ROELANDT, J ;
VANES, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :258-266
[3]   CORONARY MORPHOLOGICAL AND CLINICAL DETERMINANTS OF PROCEDURAL OUTCOME WITH ANGIOPLASTY FOR MULTIVESSEL CORONARY-DISEASE - IMPLICATIONS FOR PATIENT SELECTION [J].
ELLIS, SG ;
VANDORMAEL, MG ;
COWLEY, MJ ;
DISCIASCIO, G ;
DELIGONUL, U ;
TOPOL, EJ ;
BULLE, TM .
CIRCULATION, 1990, 82 (04) :1193-1202
[4]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[5]   SHOULD CORONARY-ARTERIES WITH LESS THAN 60-PERCENT DIAMETER STENOSIS BE TREATED BY ANGIOPLASTY [J].
ISCHINGER, T ;
GRUENTZIG, AR ;
HOLLMAN, J ;
KING, S ;
DOUGLAS, J ;
MEIER, B ;
BRADFORD, J ;
TANKERSLEY, R .
CIRCULATION, 1983, 68 (01) :148-154
[6]   CAN CORONARY ANGIOGRAPHY PREDICT THE SITE OF A SUBSEQUENT MYOCARDIAL-INFARCTION IN PATIENTS WITH MILD-TO-MODERATE CORONARY-ARTERY DISEASE [J].
LITTLE, WC ;
CONSTANTINESCU, M ;
APPLEGATE, RJ ;
KUTCHER, MA ;
BURROWS, MT ;
KAHL, FR ;
SANTAMORE, WP .
CIRCULATION, 1988, 78 (05) :1157-1166
[7]   EFFECT OF KETANSERIN ON PROXIMAL AND DISTAL CORONARY CONSTRICTOR RESPONSES TO INTRACORONARY INFUSION OF SEROTONIN IN PATIENTS WITH STABLE ANGINA, PATIENTS WITH VARIANT ANGINA, AND CONTROL PATIENTS [J].
MCFADDEN, EP ;
BAUTERS, C ;
LABLANCHE, JM ;
LEROY, F ;
CLARKE, JG ;
HENRY, M ;
SCHANDRIN, C ;
DAVIES, GJ ;
MASERI, A ;
BERTRAND, ME .
CIRCULATION, 1992, 86 (01) :187-195
[8]   LUMEN NARROWING AFTER PERCUTANEOUS TRANSLUMINAL CORONARY BALLOON ANGIOPLASTY FOLLOWS A NEAR GAUSSIAN DISTRIBUTION - A QUANTITATIVE ANGIOGRAPHIC STUDY IN 1,445 SUCCESSFULLY DILATED LESIONS [J].
RENSING, BJ ;
HERMANS, WRM ;
DECKERS, JW ;
DEFEYTER, PJ ;
TIJSSEN, JGP ;
SERRUYS, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (05) :939-945
[9]   ASSESSMENT OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY BY QUANTITATIVE CORONARY ANGIOGRAPHY - DIAMETER VERSUS DENSITOMETRIC AREA MEASUREMENTS [J].
SERRUYS, PW ;
REIBER, JHC ;
WIJNS, W ;
VANDERBRAND, M ;
KOOIJMAN, CJ ;
TENKATEN, HJ ;
HUGENHOLTZ, PG .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (06) :482-488
[10]   DOES VISUAL INTERPRETATION OF THE CORONARY ARTERIOGRAM PREDICT THE PHYSIOLOGIC IMPORTANCE OF A CORONARY STENOSIS [J].
WHITE, CW ;
WRIGHT, CB ;
DOTY, DB ;
HIRATZA, LF ;
EASTHAM, CL ;
HARRISON, DG ;
MARCUS, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (13) :819-824