DDI PACING - INDICATIONS, EXPECTATIONS, AND FOLLOW-UP

被引:8
作者
IRWIN, M [1 ]
HARRIS, L [1 ]
CAMERON, D [1 ]
LOUIS, C [1 ]
RADVANSZKY, E [1 ]
GOLDMAN, B [1 ]
机构
[1] TORONTO GEN HOSP,DIV CARDIOL & CARDIOVASC SURG,CLIN ELECTROPHYSIOL SERV,TORONTO M5G 2C4,ON,CANADA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1994年 / 17卷 / 03期
关键词
ATRIOVENTRICULAR BRADYCARDIA SUPPORT; DDI PACING; DDI FOLLOW-UP;
D O I
10.1111/j.1540-8159.1994.tb01388.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The DDI mode of pacing that permits noncompetitive atrioventricular sequential bradycardia support was chosen in 65 of 480 (14%) patients selected for dual chamber pacing between February 1985 and March 1990. All patients were implanted with Pacesetter 283 or 285 pulse generators and programmed to DDI. The indications for pacing were sick sinus syndrome (n = 52), combined sinus node dysfunction and AV block (n = 23). Forty-two of these patients had a history of paroxysmal atrial arrhythmias. Ah patients received passive fixation atrial and ventricular leads. Follow-up thereafter was performed predischarge, and at 6 weeks, 3 and 6 months after discharge. The duration of follow-up ranged from 1-61 months (mean 31 months). Fifty-four of 65 (83%) patients chosen for DDI remain programmed in the DDI mode. Three patients were reprogrammed to WI and eight to DDD. During the course of follow-up, six patients presented with effective VVI pacing with consistent ventriculoatrial conduction that was appropriately sensed by the atrial circuit with atrial output inhibition. A further four patients presented with ''functional undersensing'' due to ventricular blanking period (VBP) characteristics in these pulse generators and in this mode. Functional undersensing was eliminated in all but one patient by reprogramming the VBP to 13 msec with no subsequent episodes of provoked crosstalk inhibition. Effective VVI pacing was observed in patients with AV block during times of sinus acceleration. While DDI mode is an effective form ofpacing, permitting noncompetitive atrioventricular sequential pacing, potential limitations include: effective VVI pacing during intact ventriculoatrial conduction, functional undersensing when long VBP are programmed, and effective VVI pacing with sinus node acceleration during AV block.
引用
收藏
页码:274 / 279
页数:6
相关论文
共 20 条
[1]   DDI PACING IN THE BRADYCARDIA-TACHYCARDIA SYNDROME [J].
BANA, G ;
LOCATELLI, V ;
PIATTI, L ;
GEROSA, C ;
KNIPPEL, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (03) :264-270
[2]   CHARACTERIZATION OF PACEMAKER ARRHYTHMIAS DUE TO NORMALLY FUNCTIONING AV DEMAND (DVI) PULSE GENERATORS [J].
BAROLD, SS ;
FALKOFF, MD ;
ONG, LS ;
HEINLE, RA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1980, 3 (06) :712-723
[3]   THE DDI MODE OF CARDIAC PACING [J].
BAROLD, SS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03) :480-484
[4]   A CASE OF VENTRICULAR UNDERSENSING IN THE DDI MODE - CAUSE AND CORRECTION [J].
BERTUSO, J ;
KAPOOR, AS ;
SCHAFER, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (05) :685-689
[5]   PACEMAKER SYNDROME DUE TO RETROGRADE CONDUCTION IN A DDI PACEMAKER [J].
CUNNINGHAM, TM .
AMERICAN HEART JOURNAL, 1988, 115 (02) :478-479
[6]  
DENDULK K, 1982, PACE, V5, P476
[7]  
ERLBACHER JA, 1986, PACE, V9, P519
[8]  
FLORO J, 1984, CLIN PROG PACING ELE, V2, P255
[9]   ATRIAL-FIBRILLATION DURING AV SEQUENTIAL PACING [J].
FURMAN, S ;
COOPER, JA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1982, 5 (01) :133-135
[10]   ENDLESS LOOP TACHYCARDIA IN AN AV UNIVERSAL (DDD) PACEMAKER [J].
FURMAN, S ;
FISHER, JD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1982, 5 (04) :486-489