Preparation and functionalization of conducting polypyrrole films on different materials provide surfaces suitable to bind enzymes covalently after carbodiimide activation. The enzyme electrodes have been tested in comparison to electrodes obtained by binding of oxidases to graphite surfaces. Covalent immobilization of the glucose oxidase directly to the functionalized polypyrrole surface led to biosensors with a short response time, reaching a steady-state current within 30 s in stationary measurements and about 10 s in an automatic flow-injection system. The enzyme electrodes show good stability using oxygen as an electron acceptor, and more than 700 glucose measurements are possible with the new polypyrrole-glucose oxidase electrodes in a flow system. © 1990.
引用
收藏
页码:537 / 541
页数:5
相关论文
共 16 条
[1]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[2]   KINETIC BEHAVIOR OF ENZYMES IMMOBILIZED IN ARTIFICIAL MEMBRANES [J].
BLAEDEL, WJ ;
BOGUSLASKI, RC ;
KISSEL, TR .
ANALYTICAL CHEMISTRY, 1972, 44 (12) :2030-+
[3]   COVALENT LINKAGE OF GLUCOSE-OXIDASE ON MODIFIED GLASSY-CARBON ELECTRODES - KINETIC PHENOMENA [J].
BOURDILLON, C ;
BOURGEOIS, JP ;
THOMAS, D .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1980, 102 (12) :4231-4235
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[6]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[7]  
GENSHAW MA, 1988, CLIN CHEM, V34, P1717
[8]   AN AUTOMATIC AND STERILIZABLE SAMPLER FOR LABORATORY FERMENTERS - APPLICATION TO THE ONLINE CONTROL OF GLUCOSE-CONCENTRATION [J].
GHOUL, M ;
RONAT, E ;
ENGASSER, JM .
BIOTECHNOLOGY AND BIOENGINEERING, 1986, 28 (01) :119-121
[9]   ORGANIC METALS - POLYPYRROLE, A STABLE SYNTHETIC METALLIC POLYMER [J].
KANAZAWA, KK ;
DIAZ, AF ;
GEISS, RH ;
GILL, WD ;
KWAK, JF ;
LOGAN, JA ;
RABOLT, JF ;
STREET, GB .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1979, (19) :854-855
[10]  
KULYS JJ, 1986, BIOSENSORS, V2, P3