ERROR FIELD MEASUREMENT AND ANALYSIS FOR A PURE PERMANENT-MAGNET FEL WIGGLER

被引:2
作者
GOODMAN, DL [1 ]
SHEFER, RE [1 ]
HALBACH, K [1 ]
机构
[1] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LAB,BERKELEY,CA 94708
关键词
D O I
10.1016/0168-9002(92)91168-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A two meter long pure permanent magnet FEL wiggler with a 4 cm period and a 2.4 kG field on-axis has been fabricated and tested for the random field error parameters which are relevant to high gain FEL performance. The wiggler is part of a submillimeter-wave alpha particle Thomson scattering diagnostic for fusion plasmas. The integrated magnetic field along the electron beam trajectory was measured for each individual wiggler magnet. The magnets were sorted into a configuration which minimizes the random field-error-induced electron beam steering and displacement. A description of the magnetic field error requirements for the FEL, the error field measurement technique, measurement results and magnet sorting algorithms are presented. After sorting, a measured rms field error of less than 0.5% was obtained.
引用
收藏
页码:825 / 829
页数:5
相关论文
共 9 条