ACCURACY OF A CONTINUOUS BLOOD-PRESSURE MONITOR BASED ON ARTERIAL TONOMETRY

被引:156
作者
SATO, T
NISHINAGA, M
KAWAMOTO, A
OZAWA, T
TAKATSUJI, H
机构
[1] KOCHI MED SCH,DEPT MED,NANKOKU,KOCHI 783,JAPAN
[2] KOCHI MED SCH,DEPT GERIATR,NANKOKU,KOCHI 783,JAPAN
[3] KOCHI MED SCH,MED RES LAB,NANKOKU,KOCHI 783,JAPAN
关键词
BLOOD PRESSURE MONITORS; BLOOD PRESSURE; TONOMETRY;
D O I
10.1161/01.HYP.21.6.866
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
A validation study of the continuous noninvasive tonometric blood pressure monitor called JENTOW was performed in 20 normotensive subjects and 10 hypertensive patients. Tonometric and intra-arterial blood pressures were simultaneously recorded at supine rest and during a Valsalva maneuver and tilting test. The results of the strict evaluation of the instrument's capacity for reproducing intra-arterial blood pressure were as follows: 1) The overall frequency response of the transcutaneous blood pressure-monitoring system based on arterial tonometry was flat, with negligible delay to intra-arterial blood pressure in the range of 0-5 Hz. 2) The largest discrepancy between intra-arterial and tonometric pressure waveforms was found at the early systolic phase; except for this phase, the tonometric waveform was almost equal to the intra-arterial waveform. 3) The beat-to-beat variability of tonometric pressure corresponded to that of intra-arterial pressure almost perfectly in the physiologically significant frequency range of 0-0.5 Hz. 4) During resting conditions, the averages of the systolic and diastolic values measured tonometrically corresponded well to those measured intra-arterially. 5) The changes in the between-method discrepancy of blood pressure values during the Valsalva maneuver were statistically significant but small (<5 mm Hg). 6) No significant effect of postural tilting was found on the between-method discrepancy. We conclude that this method is clinically acceptable and reliable except for its limited capacity for recording the higher frequency intra-arterial waveform and for responding to the relatively rapid and large transient changes in blood pressure.
引用
收藏
页码:866 / 874
页数:9
相关论文
共 13 条
[1]  
BENDAT JS, 1971, RANDOM DATA ANAL MEA
[2]   ARTERIAL TONOMETRY - REVIEW AND ANALYSIS [J].
DRZEWIECKI, GM ;
MELBIN, J ;
NOORDERGRAAF, A .
JOURNAL OF BIOMECHANICS, 1983, 16 (02) :141-152
[3]  
ECKERLE JS, 1988, ENCY MED DEVICES INS, P2770
[4]  
IMHOLZ BPM, 1992, J HYPERTENS, V10, P979
[5]  
KEMMOTSU O, 1991, ANESTH ANALG, V73, P54
[6]   CARDIOVASCULAR NEURAL REGULATION EXPLORED IN THE FREQUENCY-DOMAIN [J].
MALLIANI, A ;
PAGANI, M ;
LOMBARDI, F ;
CERUTTI, S .
CIRCULATION, 1991, 84 (02) :482-492
[7]  
MULDER LJM, 1991, HOMEOSTASIS HLTH DIS, V33, P47
[8]  
O'Rourke M, 1992, ARTERIAL PULSE
[9]   COMPARISON OF FINGER AND INTRA-ARTERIAL BLOOD-PRESSURE MONITORING AT REST AND DURING LABORATORY TESTING [J].
PARATI, G ;
CASADEI, R ;
GROPPELLI, A ;
DIRIENZO, M ;
MANCIA, G .
HYPERTENSION, 1989, 13 (06) :647-655
[10]   A TRANSDUCER FOR CONTINUOUS EXTERNAL MEASUREMENT OF ARTERIAL BLOOD PRESSURE [J].
PRESSMAN, GL ;
NEWGARD, PM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1963, BM10 (02) :73-&