A STUDY TO CHARACTERIZE INDOOR PARTICLES IN 3 NONSMOKING HOMES

被引:114
作者
KAMENS, R [1 ]
LEE, CT [1 ]
WIENER, R [1 ]
LEITH, D [1 ]
机构
[1] US EPA,ATMOSPHER RES & EXPOSURE ASSESSMENT LAB,RES TRIANGLE PK,NC 27711
来源
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS | 1991年 / 25卷 / 5-6期
关键词
PARTICLES; INDOORS; NONSMOKING; CHARACTERIZATION; SIZE DISTRIBUTIONS; SOURCES;
D O I
10.1016/0960-1686(91)90136-U
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aerosol concentrations and particle size distributions in three middle income homes were characterized over a three day period. Occupants of the homes were non-smokers. A single central sampling location between the kitchen and dining room areas was used in each of the homes. Thirty-seven and 47 mm prototype personal sampling inlets were collocated with two fixed PM10 dichotomous ambient samplers to determine the average concentration of particulate mass during daytime and evening-early morning sampling periods. Particulate concentrations in the three homes ranged from 14 to 42-mu-g m-3. On average, 37% of the particle mass was collected in a fine (2.5-mu-m aerodynamic diameter or below) fraction, 26% was observed in a coarse fraction between 2.5 and 10-mu-m, and 37% was found in a fraction greater than 10-mu-m. Particle concentrations obtained with prototype personal samplers compared reasonably well to those obtained with 10-mu-m ambient air dichotomous samplers. Aerosol size information obtained from automated aerosol instruments suggests that the most significant event for generating small particles in all of the households was cooking. Household vacuum sweeping was the most significant large particle generating event. Electron photomicrographs indicated that particles below 1-mu-m dominate the particle size-number distribution. Biological and mineral based particles predominantly make up the 2.5-10-mu-m size range.
引用
收藏
页码:939 / 948
页数:10
相关论文
共 9 条
[1]  
ANDERSON R, 1989, P EPA AWMA MEASUREME, P464
[2]  
BUCKLEY TJ, 1988, P EPA APCA MEASUREME, P113
[3]   AN INTERCOMPARISON OF THE INDOOR AIR SAMPLING IMPACTOR AND THE DICHOTOMOUS SAMPLER FOR A 10-MU-M CUT SIZE [J].
LIOY, PJ ;
WAINMAN, T ;
TURNER, W ;
MARPLE, VA .
JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (05) :668-670
[4]   THE PERSONAL, INDOOR AND OUTDOOR CONCENTRATIONS OF PM-10 MEASURED IN AN INDUSTRIAL COMMUNITY DURING THE WINTER [J].
LIOY, PJ ;
WALDMAN, JM ;
BUCKLEY, T ;
BUTLER, J ;
PIETARINEN, C .
ATMOSPHERIC ENVIRONMENT PART B-URBAN ATMOSPHERE, 1990, 24 (01) :57-66
[5]   DICHOTOMOUS SAMPLERS MODIFIED FOR USE WITH ELECTRON-MICROSCOPY [J].
MAMANE, Y ;
DZUBAY, TG .
AEROSOL SCIENCE AND TECHNOLOGY, 1990, 13 (02) :241-248
[6]  
MCCRONE WC, 1980, PARTICLE ATLAS
[7]   INDOOR OUTDOOR AEROSOL MEASUREMENTS FOR 2 RESIDENTIAL BUILDINGS IN NEW-JERSEY [J].
TU, KW ;
KNUTSON, EO .
AEROSOL SCIENCE AND TECHNOLOGY, 1988, 9 (01) :71-82
[8]  
WIENER RW, 1988, P EPA AWMA S MEAS TO, P84
[9]  
1987, APPENDIX A PRELIMINA