CONTINUOUS-FLOW THIN-LAYER HEADSPACE (TLHS) ANALYSIS .3. POTENTIOMETRIC DETERMINATION OF VOLATILE ORGANIC HALOGENS (VOX) IN WATER

被引:12
作者
KOZLOWSKI, E
GORECKI, T
SIENKOWSKAZYSKOWSKA, E
机构
[1] Institute of Inorganic Chemistry, Technology and Corrosion, Chemical Faculty, Technical University of Gdańsk, Gdańsk, PL-80-952
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1991年 / 340卷 / 07期
关键词
D O I
10.1007/BF00322421
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper presents a new method of a continuous isolation and determination of volatile organic halogens (VOX) in drinking waters based on so-called thin layer headspace (TLHS) isolation technique. The liberated volatile compounds are mineralized in an empty quartz tube at 850-degrees-C and absorbed in a buffered washing solution. After separation of air the halogen ions are determined potentiometrically in a flow-through cell using a silver/silver choride indicating electrode. The potential of the electrode is a linear function of the halogen ion concentration in the washing solution within the VOX concentration range usually encountered in drinking waters. The estimated detection limit of the method is ca. 0.1-mu-g/l VOX and can be further improved by increasing the concentration factor. The theory of the TLHS isolation method has been further developed and verified. The derived dependences enable a simultaneous determination of the effective partition coefficients in the system, thus enabling calculation of the optimal gas flow rate.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 6 条
[1]  
Cammann K., 1973, ARBEITEN IONENSELEKT
[2]  
ELKHORDAGNI HK, 1983, WATER QUALITY B, V8, P39
[3]   CONTINUOUS-FLOW THIN-LAYER HEADSPACE (TLHS) ANALYSIS .1. CONDUCTOMETRIC DETERMINATION OF VOLATILE ORGANIC HALOGENS (VOX) IN TAP WATER [J].
KOZLOWSKI, E ;
SIENKOWSKAZYSKOWSKA, E ;
GORECKI, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (01) :19-25
[4]   CONTINUOUS-FLOW THIN-LAYER HEADSPACE (TLHS) ANALYSIS .2. SPECTROPHOTOMETRIC DETERMINATION OF VOLATILE ORGANIC HALOGENS (VOX) IN WATER [J].
KOZLOWSKI, E ;
SIENKOWSKAZYSKOWSKA, E ;
GORECKI, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (12) :882-885
[5]   POTENTIOMETRIC SYSTEM FOR CONTINUOUS DETERMINATION OF LOW-LEVELS OF CHLORIDE IN HIGH-PURITY POWER-STATION WATERS [J].
TOMLINSON, K ;
TORRANCE, K .
ANALYST, 1977, 102 (1210) :1-8
[6]   POTENTIOMETRIC METHOD FOR DETERMINATION OF CHLORIDE IN BOILER WATERS IN RANGE 0.1 TO 10MUG M1-1 OF CHLORIDE [J].
TORRANCE, K .
ANALYST, 1974, 99 (1177) :203-210