COMPETITIVE FLOW FROM A FULLY PATENT CORONARY-ARTERY DOES NOT LIMIT ACUTE MAMMARY GRAFT FLOW

被引:34
作者
SPENCE, PA [1 ]
LUST, RM [1 ]
ZERI, RS [1 ]
JOLLY, SR [1 ]
MEHTA, PM [1 ]
OTAKI, M [1 ]
YOU, SS [1 ]
CHITWOOD, WR [1 ]
GUNDRY, SR [1 ]
VERRIER, EA [1 ]
BECKMAN, CB [1 ]
LESTER, JL [1 ]
机构
[1] E CAROLINA UNIV,SCH MED,DIV CARDIOL,GREENVILLE,NC 27834
关键词
D O I
10.1016/0003-4975(92)91134-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The shriveled, stenotic mammary graft sometimes observed after internal mammary artery (IMA) to coronary artery bypass grafting has been attributed to competitive flow from the insufficiently stenosed native coronary vessel. To study further the effects of native coronary artery competing flow on IMA graft flow, 10 dogs (mean weight, 23.5 +/- 3.69 kg) underwent coronary artery bypass grafting using the pedicled left IMA anastomosed to a normal, fully patent proximal circumflex (CFX) coronary artery. The procedure was performed through a left thoracotomy, off pump, using a brief local occlusion to perform the anastomosis. Native in situ IMA flow, CFX flow distal to the anastomosis, and IMA graft flow were measured using calibrated electromagnetic flow probes. When the CFX proximal to the anastomosis was occluded transiently, IMA flow increased to supply 100% of the previously measured distal CFX flow (60.2 +/- 7.9 mL/min). When both the IMA graft and CFX proximal to the anastomosis were patent, total distal perfusion was maintained (58.9 +/- 7.8 mL/min) and relative IMA graft flow (26.5 +/- 3.3 mL/min) was proportional to the relative diameter of the IMA graft to the native coronary artery (r = 0.96). The mean flow in the IMA in situ on the chest wall before its division was 23.8 +/- 8.1 mL/min. These results suggest that, at least acutely in a canine model, IMA graft flow is maintained above in situ levels even when grafted to a completely patent coronary artery and that acute competitive flow probably does not cause mammary artery shriveling.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 7 条
[1]  
BARNER HB, 1974, ARCH SURG-CHICAGO, V109, P627
[2]  
DINCER B, 1983, J THORAC CARDIOV SUR, V85, P318
[3]   EARLY AND LATE RESULTS OF CORONARY REVASCULARIZATION WITH SAPHENOUS-VEIN AND INTERNAL MAMMARY ARTERY GRAFTS [J].
GEHA, AS ;
BAUE, AE .
AMERICAN JOURNAL OF SURGERY, 1979, 137 (04) :456-463
[4]   ANGIOGRAPHIC DEMONSTRATION OF NO-FLOW ANATOMICAL PATENCY OF INTERNAL THORACIC CORONARY-ARTERY BYPASS GRAFTS [J].
KITAMURA, S ;
KAWACHI, K ;
SEKI, T ;
SAWABATA, N ;
MORITA, R ;
KAWATA, T .
ANNALS OF THORACIC SURGERY, 1992, 53 (01) :156-159
[5]  
MCCARTHY PM, 1988, J THORAC CARDIOV SUR, V96, P30
[6]  
MULLERWORTH MH, 1975, J THORAC CARDIOV SUR, V70, P89
[7]  
URSCHEL HC, 1990, J THORAC CARDIOV SUR, V99, P581