PRINTED LOW VELOCITY DELAY-LINES FOR CATHODE READOUT OF PROPORTIONAL CHAMBERS

被引:8
作者
BOSSHARD, R [1 ]
CHASE, RL [1 ]
FISCHER, J [1 ]
IWATA, S [1 ]
RADEKA, V [1 ]
机构
[1] BROOKHAVEN NATL LAB,UPTON,NY 11973
关键词
D O I
10.1109/TNS.1975.4328064
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:2053 / 2057
页数:5
相关论文
共 15 条
[1]  
ATAC M, TO BE PUBLISHED
[2]  
BEARDSWORTH E, BNL19878 REP
[3]  
BINNS KJ, ELECTRIC MAGNETIC FI, P193
[4]   NANOSECOND BIFILAR WOUND TRANSFORMERS [J].
BOSSHARD, R ;
ZAJDE, C ;
ZYNGIER, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (07) :942-&
[5]   2-DIMENSIONAL DRIFT CHAMBERS [J].
BRESKIN, A ;
CHARPAK, G ;
SAULI, F ;
SANTIARD, JC .
NUCLEAR INSTRUMENTS & METHODS, 1974, 119 (01) :1-5
[6]  
CHARPAK G, 1973, INT C HIGH ENERGY PH, P250
[7]   MULTIWIRE PROPORTIONAL COUNTER WITH INTEGRAL READOUT DELAY-LINE [J].
GILLAND, JR ;
EMMING, JG .
NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (01) :241-&
[8]  
GROVE R, 1970, NUCL INSTRUM METHODS, V99, P381
[9]   HIGH-RESOLUTION READOUT OF MULTIWIRE PROPORTIONAL-COUNTERS USING CATHODE-COUPLED DELAY-LINE TECHNIQUE [J].
LACY, JL ;
LINDSEY, RS .
NUCLEAR INSTRUMENTS & METHODS, 1974, 119 (03) :483-498
[10]   BIFILAR HELICAL MULTIWIRE PROPORTIONAL CHAMBER FOR POSITION SENSITIVE DETECTION OF MINIMUM IONIZING PARTICLES [J].
LEE, DM ;
THIESSEN, HA ;
SOBOTTKA, SE .
NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (01) :179-&