EFFECTS OF ELECTROSTATIC FORCE RELATIVE HUMIDITY HEATING SURFACE TEMPERATURE AND SIZE AND SHAPE ON DROPLET EVAPORATION RATE

被引:9
作者
AYLOR, D
BRADFIELD, WS
机构
[1] State University of New York at Stony Brook, Stony Brook, N. Y.
来源
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS | 1969年 / 8卷 / 01期
关键词
D O I
10.1021/i160029a003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An empirical comparison was made between the evaporation rates of film boiling droplets with and without applied electrostatic voltage. Only small increases were observed and this compared favorably with the prediction of a simple parallel plate capacitor model. Qualitative descriptions based on empirical observations of the effects of liquid-solid contact, arcing, and forced convection inside the droplet on heat flow are given. Information concerning droplet shape as a function of volume is important for the prediction of droplet evaporation rates. A semi-empirical correlation is presented which fits the rate data in the spheroidal regime within 15%. © 1969, American Chemical Society. All rights reserved.
引用
收藏
页码:8 / +
页数:1
相关论文
共 14 条
[1]  
BAUMEISTER KJ, 1966, 3 P INT HEAT TRANSF
[2]  
BAUMEISTER KJ, 1965, D3133 TN NAT AER SPA
[3]  
Berenson P.J., 1962, INT J HEAT MASS TRAN, V5, P985, DOI DOI 10.1016/0017-9310(62)90079-0
[4]   LIQUID-SOLID CONTACT IN STABLE FILM BOILING [J].
BRADFIELD, WS .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1966, 5 (02) :200-+
[5]  
BRADFIELD WS, 1965, JUN P S 2PHAS FLOW U, V2, pA301
[6]  
CESS RD, 1963, FUNDAMENTALS HEAT ED, P374
[7]  
GOTTFRIED BS, 1962, THESIS CASE I TECHNO
[8]  
KUTATELADZE SS, 1963, FUNDAMENTALS HEAT TR, P374
[9]   THE EFFECT OF APPLIED VOLTAGE ON BOILING HEAT TRANSFER [J].
MARKELS, M ;
DURFEE, RL .
AICHE JOURNAL, 1964, 10 (01) :106-110
[10]   STUDIES OF BOILING HEAT TRANSFER WITH ELECTRICAL FIELDS .I. EFFECT OF APPLIED AC VOLTAGE ON BOILING HEAT TRANSFER TO WATER IN FORCED CIRCULATION [J].
MARKELS, M ;
DURFEE, RL .
AICHE JOURNAL, 1965, 11 (04) :716-&