FREE-MOMENT CURRENT DIPOLES IN INVERSE ELECTROCARDIOGRAPHY

被引:27
作者
ROGERS, CL
PILKINGTON, TC
机构
[1] Department of Electrical Engineering, Auburn University, Auburn, Ala.
[2] Division of Biomedical Engineering, Duke University, Durham, N. C.
关键词
D O I
10.1109/TBME.1968.4502583
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A feasibility study is made of the multiple free-moment dipole equivalent cardiac source concept as applied to the inverse problem in electrocardiology. The study deals with a bounded homogeneous model of a dog from which extensive geometry and potential measurements were taken. Torso surface potentials are related to the dipole sources through a set of 268 overdetermined linear algebraic equations. Three source configurations are modeled, 76, 20, and 9 dipoles, and simulation studies are made to evaluate the performance of the models and the feasibility of the concept. Inverse solutions are determined subject to a least-squares error fit of the infinite medium potentials. It is found that the number of free dipoles that can be used as an inverse source model is limited by the solution noise sensitivity, and that the upper limit is in the neighborhood of twenty. The results show that the solutions are unstable in the presence of small geometry perturbations. Localized activation simulated by the 76-dipole source cannot be detected in either the 20- or the 9-dipole solutions, even in the absence of noise and perturbations. Solutions calculated from potentials measured in vivo yield results that are unphysiologic. Copyright © 1968 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:312 / +
页数:1
相关论文
共 17 条
[1]   DETERMINING SURFACE POTENTIALS FROM CURRENT DIPOLES WITH APPLICATION TO ELECTROCARDIOGRAPHY [J].
BARR, RC ;
PILKINGTON, TC ;
BOINEAU, JP ;
SPACH, MS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1966, BM13 (02) :88-+
[2]   ESTIMATION OF HEART PARAMETERS USING SKIN POTENTIAL MEASUREMENTS [J].
BELLMAN, R ;
COLLIER, C ;
KAGIWADA, H ;
KALABA, R ;
SELVESTER, R .
COMMUNICATIONS OF THE ACM, 1964, 7 (11) :666-668
[3]   TIME-NORMALIZED CORRELATION OF VENTRICULAR ACTIVATION AND VECTORCARDIOGRAM [J].
BOINEAU, JP ;
SPACH, MS ;
AYERS, CR .
AMERICAN HEART JOURNAL, 1967, 73 (01) :64-&
[4]   DETERMINATION OF THE RESULTANT DIPOLE OF THE HEART FROM MEASUREMENTS ON THE BODY SURFACE [J].
GABOR, D ;
NELSON, CV .
JOURNAL OF APPLIED PHYSICS, 1954, 25 (04) :413-416
[5]  
HORAN LG, 1967, MEDICAL RESEARCH ENG
[6]  
KELLOG OD, 1953, FOUNDATIONS POTENTIA
[7]  
KIRK WL, 1966, P ACEMB, P192
[8]  
LANCZOS C, 1964, APPLIED ANALYSIS
[9]   A PROPOSED METHOD FOR INVERSE PROBLEM IN ELECTTROCARDIOLOGY [J].
LYNN, MS ;
BARNARD, ACL ;
HOLT, JH ;
SHEFFIELD, LT .
BIOPHYSICAL JOURNAL, 1967, 7 (06) :925-+
[10]  
PANOFSKY WKH, 1962, CLASSICAL ELECTRICIT