COMPARISON OF DOPAMINE TO DOBUTAMINE AND NOREPINEPHRINE FOR OXYGEN DELIVERY AND UPTAKE IN SEPTIC SHOCK

被引:44
作者
HANNEMANN, L
REINHART, K
GRENZER, O
MEIERHELLMANN, A
BREDLE, DL
机构
[1] UNIV JENA,O-6900 JENA,GERMANY
[2] NE OHIO UNIV,COLL MED,ROOTSTOWN,OH
关键词
SEPTIC SHOCK; OXYGEN CONSUMPTION; DOPAMINE; CATECHOLAMINES; INOTROPIC AGENTS; DOBUTAMINE; NOREPINEPHRINE; HEMODYNAMICS;
D O I
10.1097/00003246-199512000-00004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To test whether dopamine infusion improves oxygen delivery (D over dot O-2) and oxygen uptake (V over dot O-2) in hyperdynamic septic shock patients stabilized by adequate volume and dobutamine alone, or by the combination of dobutamine and norepinephrine. Design: Prospective clinical trial of two patient groups. Group 1 (n = 15) was stabilized with dobutamine, and group 2 (n = 10) was stabilized with dobutamine and norepinephrine. Setting: Intensive care unit in a university hospital. Patients: Twenty-five postoperative, hyperdynamic septic shock patients. Interventions: The stabilizing catecholamine infusion was replaced in a stepwise manner by dopamine to achieve a similar mean arterial pressure (dopamine doses: group 1, mean 22 +/- 15 mu g/kg/min [range 6 to 52]; and group 2, mean 57 +/- 41 mu g/kg/min [range 15 to 130]). Measurements and Main Results: A complete hemodynamic profile was performed with oxygen transport-related variables at baseline, after replacement by dopamine and after resetting to the original catecholamine infusion. The change to dopamine resulted in increases in cardiac index (group 1: 20% [p < .01]; group 2: 33% [p < .01]), and D over dot O-2 (group 1: 19% [p < .01]; group 2: 27% [p < .01]). However, V over dot O-2, whether directly measured from the respiratory gases or calculated by the cardiovascular Fick principle, did not change in both groups with dopamine, while the oxygen extraction ratio decreased significantly in both groups with dopamine. Heart rate, pulmonary artery occlusion pressure, and pulmonary shunt fraction all increased with dopamine, Pao(2) decreased, but oxygen saturation remained stable in both groups with dopamine. Conclusions: Short-term dopamine infusion in hyperdynamic septic shock patients, de. spite producing higher global D over dot O-2, was not superior to dobutamine or the combination of dobutamine and norepinephrine infusion.
引用
收藏
页码:1962 / 1970
页数:9
相关论文
共 34 条
[1]  
[Anonymous], 1963, CRITICAL VALUES PROB
[2]   EFFECTS OF NOREPINEPHRINE AND DOBUTAMINE ON OXYGEN-TRANSPORT AND CONSUMPTION IN A DOG-MODEL OF ENDOTOXIC-SHOCK [J].
BAKKER, J ;
VINCENT, JL .
CRITICAL CARE MEDICINE, 1993, 21 (03) :425-432
[3]   A CONTROLLED CLINICAL-TRIAL OF HIGH-DOSE METHYLPREDNISOLONE IN THE TREATMENT OF SEVERE SEPSIS AND SEPTIC SHOCK [J].
BONE, RC ;
FISHER, CJ ;
CLEMMER, TP ;
SLOTMAN, GJ ;
METZ, CA ;
BALK, RA .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (11) :653-658
[4]  
BRETSCHNEIDER HJ, 1971, P INT C MUNICH P INT, P663
[5]   RELATIONSHIP BETWEEN OXYGEN-UPTAKE AND OXYGEN DELIVERY IN SEPTIC PATIENTS - EFFECTS OF PROSTACYCLIN VERSUS DOBUTAMINE [J].
DEBACKER, D ;
BERRE, J ;
ZHANG, HB ;
KAHN, RJ ;
VINCENT, JL .
CRITICAL CARE MEDICINE, 1993, 21 (11) :1658-1664
[6]   A REAPPRAISAL OF NOREPINEPHRINE THERAPY IN HUMAN SEPTIC SHOCK [J].
DESJARS, P ;
PINAUD, M ;
POTEL, G ;
TASSEAU, F ;
TOUZE, MD .
CRITICAL CARE MEDICINE, 1987, 15 (02) :134-137
[7]  
FLECKENSTEIN W, 1984, ADV EXP MED BIOL, V180, P609
[8]   THE EFFECT OF FLUID LOADING, BLOOD-TRANSFUSION, AND CATECHOLAMINE INFUSION ON OXYGEN DELIVERY AND CONSUMPTION IN PATIENTS WITH SEPSIS [J].
GILBERT, EM ;
HAUPT, MT ;
MANDANAS, RY ;
HUARINGA, AJ ;
CARLSON, RW .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 134 (05) :873-878
[9]  
GIRAUD GD, 1984, J PHARMACOL EXP THER, V230, P214
[10]   GASTRIC INTRAMUCOSAL PH AS A THERAPEUTIC INDEX OF TISSUE OXYGENATION IN CRITICALLY ILL PATIENTS [J].
GUTIERREZ, G ;
PALIZAS, F ;
DOGLIO, G ;
WAINSZTEIN, N ;
GALLESIO, A ;
PACIN, J ;
DUBIN, A ;
SCHIAVI, E ;
JORGE, M ;
PUSAJO, J ;
KLEIN, F ;
ROMAN, ES ;
DORFMAN, B ;
SHOTTLENDER, J ;
GINIGER, R .
LANCET, 1992, 339 (8787) :195-199