APPLICATION OF MATHEMATICAL REMOVAL OF POSITRON RANGE BLURRING IN POSITRON EMISSION TOMOGRAPHY

被引:40
作者
HABER, SF
DERENZO, SE
UBER, D
机构
[1] Lawrence Berkeley Laboratory, University of California, Berkeley
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.57379
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The range of positrons in tissue is an important limitation to the ultimate spatial resolution achievable in Positron Emission Tomography. In this work we applied a Fourier deconvolution technique to remove range blurring in images taken by the Donner 600-Crystal Positron Tomograph. Using phantom data, we found significant improvement in the image quality and the FWHM for both 68Ga and 82Rb. These were successfully corrected so that the images and FWHM almost matched those of 18F which has negligible positron range. However, statistical noise was increased by the deconvolution process and it was not practical to recover the full spatial resolution of the tomograph. © 1990 IEEE
引用
收藏
页码:1293 / 1299
页数:7
相关论文
共 10 条
  • [1] THE ELECTRONICS FOR THE DONNER 600-CRYSTAL POSITRON TOMOGRAPH
    CAHOON, JL
    HUESMAN, RH
    DERENZO, SE
    GEYER, AB
    UBER, DC
    TURKO, BT
    BUDINGER, TF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 570 - 574
  • [2] INITIAL RESULTS FROM THE DONNER-600 CRYSTAL POSITRON TOMOGRAPH
    DERENZO, SE
    HUESMAN, RH
    CAHOON, JL
    GEYER, A
    UBER, D
    VULETICH, T
    BUDINGER, TF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 321 - 325
  • [3] MATHEMATICAL REMOVAL OF POSITRON RANGE BLURRING IN HIGH-RESOLUTION TOMOGRAPHY
    DERENZO, SE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 565 - 569
  • [4] A POSITRON TOMOGRAPH WITH 600-BGO CRYSTALS AND 2.6 MM RESOLUTION
    DERENZO, SE
    HUESMAN, RH
    CAHOON, JL
    GEYER, AB
    MOSES, WW
    UBER, DC
    VULETICH, T
    BUDINGER, TF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 659 - 664
  • [5] DERENZO SE, 1990, LABORATORY APPROACH, P329
  • [6] DERENZO SE, 1979, POSITRON ANNIHILATIO, P819
  • [7] HUESMAN RH, 1983, NUCL MED BIOL, V1, P542
  • [8] 3-DIMENSIONAL RECONSTRUCTION FROM RADIOGRAPHS AND ELECTRON MICROGRAPHS - APPLICATION OF CONVOLUTIONS INSTEAD OF FOURIER TRANSFORMS
    RAMACHANDRAN, GN
    LAKSHMINARAYANAN, AV
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1971, 68 (09) : 2236 - +
  • [9] FOURIER RECONSTRUCTION OF A HEAD SECTION
    SHEPP, LA
    LOGAN, BF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (03) : 21 - 43
  • [10] SCINTILLATION PHOTON DETECTION AND EVENT SELECTION IN HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY
    TURKO, BT
    ZIZKA, G
    LO, CC
    LESKOVAR, B
    CAHOON, JL
    HUESMAN, RH
    DERENZO, SE
    GEYER, AB
    BUDINGER, TF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 326 - 331