A TIME DOMAIN APPROACH FOR THE FLUCTUATION ANALYSIS OF HEART-RATE RELATED TO INSTANTANEOUS LUNG-VOLUME

被引:57
作者
YANA, K
SAUL, JP
BERGER, RD
PERROTT, MH
COHEN, RJ
机构
[1] MIT,DIV HLTH SCI & TECHNOL,CAMBRIDGE,MA 02139
[2] JOHNS HOPKINS UNIV HOSP,BALTIMORE,MD 21205
[3] BRIGHAM & WOMENS HOSP,BOSTON,MA 02115
[4] CHILDRENS HOSP MED CTR,BOSTON,MA 02115
[5] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
D O I
10.1109/10.204773
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a time domain technique for estimating transfer characteristics from fluctuations of instantaneous lung volume (ILV) to heart rate (HR). An effective procedure for estimating the impulse response of HR to ILV is proposed. Pre- and post-processing procedures, including prefiltering of the HR signal, preenhancement of the high frequency content of the ILV signal, and post-filtering of the estimated impulse response, together with a random breathing technique, are shown to effectively reduce spurious transfer gain so as to get a stable estimate of the impulse response. Analysis of the data collected from fourteen healthy male subjects in various conditions revealed that there are three components in the impulse response: fast positive, delayed slow negative, and oscillatory. The effects of the autonomic blocking agents propranolol and atropine on these transfer characteristics are also described.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 32 条
[1]   HEMODYNAMIC REGULATION - INVESTIGATION BY SPECTRAL-ANALYSIS [J].
AKSELROD, S ;
GORDON, D ;
MADWED, JB ;
SNIDMAN, NC ;
SHANNON, DC ;
COHEN, RJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 249 (04) :H867-H875
[2]   POWER SPECTRUM ANALYSIS OF HEART-RATE FLUCTUATION - A QUANTITATIVE PROBE OF BEAT-TO-BEAT CARDIOVASCULAR CONTROL [J].
AKSELROD, S ;
GORDON, D ;
UBEL, FA ;
SHANNON, DC ;
BARGER, AC ;
COHEN, RJ .
SCIENCE, 1981, 213 (4504) :220-222
[3]   BEAT TO BEAT VARIABILITY IN CARDIOVASCULAR VARIABLES - NOISE OR MUSIC [J].
APPEL, ML ;
BERGER, RD ;
SAUL, JP ;
SMITH, JM ;
COHEN, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1139-1148
[4]  
APPEL ML, 1990, COMPUT CARDIOL, V16, P3
[5]   SPECTRAL AND CROSS-SPECTRAL ANALYSIS OF HEART-RATE AND ARTERIAL BLOOD-PRESSURE VARIABILITY SIGNALS [J].
BASELLI, G ;
CERUTTI, S ;
CIVARDI, S ;
LIBERATI, D ;
LOMBARDI, F ;
MALLIANI, A ;
PAGANI, M .
COMPUTERS AND BIOMEDICAL RESEARCH, 1986, 19 (06) :520-534
[6]   CARDIOVASCULAR VARIABILITY SIGNALS - TOWARDS THE IDENTIFICATION OF A CLOSED-LOOP MODEL OF THE NEURAL CONTROL MECHANISMS [J].
BASELLI, G ;
CERUTTI, S ;
CIVARDI, S ;
MALLIANI, A ;
PAGANI, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (12) :1033-1046
[7]   AN EFFICIENT ALGORITHM FOR SPECTRAL-ANALYSIS OF HEART-RATE-VARIABILITY [J].
BERGER, RD ;
AKSELROD, S ;
GORDON, D ;
COHEN, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (09) :900-904
[8]   ASSESSMENT OF AUTONOMIC RESPONSE BY BROAD-BAND RESPIRATION [J].
BERGER, RD ;
SAUL, JP ;
COHEN, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (11) :1061-1065
[9]  
BERGER RD, 1988, 10TH P ANN INT C IEE, P533
[10]   POSITIVE CHRONOTROPIC EFFECT OF INCREASING RIGHT ATRIAL PRESSURE IN THE ISOLATED MAMMALIAN HEART [J].
BLINKS, JR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1956, 186 (02) :299-303