PERFORMANCE OF SUBCUTANEOUSLY IMPLANTED NEEDLE-TYPE GLUCOSE SENSORS EMPLOYING A NOVEL TRILAYER COATING

被引:143
作者
MOUSSY, F
HARRISON, DJ
OBRIEN, DW
RAJOTTE, RV
机构
[1] UNIV ALBERTA,DEPT CHEM,EDMONTON T6G 2G2,ALBERTA,CANADA
[2] UNIV ALBERTA,SURG MED RES INST,EDMONTON T6G 2N8,ALBERTA,CANADA
[3] UNIV ALBERTA,DEPT SURG & MED,EDMONTON T6G 2N8,ALBERTA,CANADA
关键词
D O I
10.1021/ac00063a023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniature, needle-type glucose sensor based on a new trilayer membrane configuration has been prepared and evaluated both in vitro and in vivo. The perfluorinated ionomer, Nafion, was used as a protective, biocompatible, outer coating, and poly(o-phenylenediamine) as an inner coating to reduce interference by small, electroactive compounds. Glucose oxidase immobilized in a bovine serum albumin matrix was sandwiched between these coatings. The entire sensor assembly of Pt working electrode and Ag/AgCl reference electrode was 0.5 mm in diameter and could be inserted subcutaneously through an 18-gauge needle. The sensor current closely followed the plasma glucose level during a glucose tolerance test in active dogs, with a delay of 3 min, corresponding to the known lag time for subcutaneous glucose levels. The sensor remained functional after 1 week of implantation, but failed after 2 weeks due to degradation of the reference electrode. In vitro tests in pH 7.4 buffer or whole blood show the sensors have good selectivity, sensitivity of about 25 nA/mM, precision of 2-5%, and a 90% response time of 33 s. Stabilization following polarization requires 10-30 min in vitro and 30-40 min in vivo.
引用
收藏
页码:2072 / 2077
页数:6
相关论文
共 25 条
[1]  
ALBISSER AM, 1974, DIABETRES, V3, P397
[2]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[3]   IMPLANTED ELECTROENZYMATIC GLUCOSE SENSORS [J].
CLARK, LC ;
DUGGAN, CA .
DIABETES CARE, 1982, 5 (03) :174-180
[4]  
EISENBERG A, 1982, ACS S SERIES, V180
[5]   PERMEABILITY OF GLUCOSE AND OTHER NEUTRAL SPECIES THROUGH RECAST PERFLUOROSULFONATED IONOMER FILMS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1992, 64 (11) :1304-1311
[6]  
FISHER U, 1987, DIABETOLOGIA, V30, P940
[7]   TWO-DIMENSIONAL ENZYME ELECTRODE SENSOR FOR GLUCOSE [J].
GOUGH, DA ;
LUCISANO, JY ;
TSE, PHS .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2351-2357
[8]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[9]  
IKEDA S, 1983, P CHEM SENS, V17, P620
[10]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740