UNIQUE QUALITY ASSURANCE ASPECTS OF INAA FOR REFERENCE MATERIAL HOMOGENEITY AND CERTIFICATION

被引:21
作者
BECKER, DA
机构
[1] Nuclear Methods Group, Inorganic Analytical Research Division/CSTL, National Institute of Standards and Technology, Gaithersburg, 20899, MD
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1993年 / 345卷 / 2-4期
关键词
D O I
10.1007/BF00322615
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Instrumental neutron activation analysis (INAA) has become one of the primary analytical techniques for certification of elemental content in biological Standard Reference Materials (SRMs) at the National Institute of Standards and Technology (NIST). One important reason why INAA has become so widely used and valuable in the certification of NIST SRMs is that INAA has unique inherent quality assurance (QA) characteristics which provide the capability for accurate analysis and which often allow the analytical values obtained to be internally evaluated and cross checked. While the NAA technique has the general characteristics of most spectroscopic techniques, the specific characteristics include uniform activation, long and well-documented excited states, highly penetrating emitted radiation, and an excited state decay process which is statistically random in nature. These characteristics work together to provide an analytical technique which can provide highly reliable analytical results and is particularly suitable for the certification of major, minor, and trace elements in biological reference materials.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 11 条
[1]  
BECKER D, 1990, BIOL TRACE ELEMENT R, P571
[2]   CHARACTERIZATION OF A NUCLEAR-REACTOR FOR NEUTRON-ACTIVATION ANALYSIS [J].
BECKER, DA ;
LAFLEUR, PD .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1974, 19 (01) :149-157
[3]   THE ROLE OF REACTOR CHARACTERIZATION IN NAA QUALITY ASSURANCE [J].
BECKER, DA .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 110 (02) :393-401
[4]   THE USE OF HIGH-ACCURACY NAA FOR THE CERTIFICATION OF NIST BOTANICAL STANDARD REFERENCE MATERIALS [J].
BECKER, DA ;
GREENBERG, RR ;
STONE, SF .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 160 (01) :41-53
[5]  
BECKER DA, IN PRESS J RADIOANAL
[6]  
BECKER DA, 1989, NIST1272 TECH NOT, P238
[7]  
BECKER DA, 1985, NBS1217 TECHN NOT, P120
[8]  
GLADNEY ES, 1987, NBS SPEC PUBL, P260
[9]   DISSOLUTION PROBLEMS WITH BOTANICAL REFERENCE MATERIALS [J].
GREENBERG, RR ;
KINGSTON, HM ;
WATTERS, RL ;
PRATT, KW .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (04) :394-398
[10]   CHARACTERIZATION OF THE MINERAL FRACTION IN BOTANICAL REFERENCE MATERIALS AND ITS INFLUENCE ON HOMOGENEITY AND ANALYTICAL RESULTS [J].
LINDSTROM, RM ;
BYRNE, AR ;
BECKER, DA ;
SMODIS, B ;
GARRITY, KM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (04) :569-571