DIGITAL DIPYRIDAMOLE STRESS ECHOCARDIOGRAPHY IN SILENT ISCHEMIA AFTER CORONARY-ARTERY BYPASS-GRAFTING AND OR AFTER HEALING OF ACUTE MYOCARDIAL-INFARCTION

被引:19
作者
BJOERNSTAD, K [1 ]
AAKHUS, S [1 ]
LUNDBOM, J [1 ]
BOLZ, KD [1 ]
ROKSETH, R [1 ]
SKJAERPE, T [1 ]
HATLE, L [1 ]
机构
[1] UNIV HOSP TRONDHEIM,DEPT RADIOL,N-7006 TRONDHEIM,NORWAY
关键词
D O I
10.1016/0002-9149(93)90877-F
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluates dipyridamole stress echocardiography in silent ischemia. Fourteen patients with previous coronary artery bypass grafting (group A) and 16 patients with healed myocardial infarction (group B) were studied. All had 1 mm ST depression without chest pain during bicycle exercise testing. Left ventricular wall motion was analyzed using a computerized display of digital systolic cineloops with a high frame rate. Test results were compared with coronary angiography. Dipyridamole echocardiography accurately identified patients with significant coronary artery stenosis in both groups (3 of 4 in group A, 11 of 14 in group B). Retrograde flow to the occluded native artery was associated with positive results on dipyridamole testing in 6 of 7 patients in group A and all 3 in group B. Sensitivity, specificity and diagnostic accuracy for detecting significant coronary stenosis or occlusions with retrograde flow was 78, 100 and 83%, respectively. Patients with angiographic multivessel disease had a significantly larger increase in wall motion score index during dipyridamole stress than patients with 0- or 1-vessel disease, 0.18 +/- 0.11 versus 0.05 +/- 0.18 (p < 0.05). Two patients developed symptomatic bradycardia and hypotension during dipyridamole infusion. It is concluded that dipyridamole echocardiography accurately identifies myocardial regions with restricted coronary flow. Stress echocardiography is a valuable tool for assessing coronary flow in silent ischemia.
引用
收藏
页码:640 / 646
页数:7
相关论文
共 28 条
  • [1] EFFECT OF PRIOR MYOCARDIAL-INFARCTION AND EXTENT AND LOCATION OF CORONARY-DISEASE ON ACCURACY OF EXERCISE ECHOCARDIOGRAPHY
    ARMSTRONG, WF
    ODONNELL, J
    RYAN, T
    FEIGENBAUM, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) : 531 - 538
  • [2] BIAGINI A, 1991, J THORAC CARDIOV SUR, V101, P116
  • [3] HIGH-DOSE DIPYRIDAMOLE ECHOCARDIOGRAPHY EARLY AFTER UNCOMPLICATED ACUTE MYOCARDIAL-INFARCTION - CORRELATION WITH EXERCISE TESTING AND CORONARY ANGIOGRAPHY
    BOLOGNESE, L
    SARASSO, G
    ARALDA, D
    BONGO, AS
    ROSSI, L
    ROSSI, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (02) : 357 - 363
  • [4] DIPYRIDAMOLE ECHOCARDIOGRAPHY TEST - A NEW TOOL FOR DETECTING JEOPARDIZED MYOCARDIUM AFTER THROMBOLYTIC THERAPY
    BOLOGNESE, L
    SARASSO, G
    BONGO, AS
    ROSSI, L
    ARALDA, D
    PICCININO, C
    ROSSI, P
    [J]. CIRCULATION, 1991, 84 (03) : 1100 - 1106
  • [5] COHN PF, 1990, CIRCULATION, V82, P149
  • [6] USE OF THE EXERCISE TEST TO PREDICT PROGNOSIS AFTER CORONARY-ARTERY BYPASS-GRAFTING
    DUBACH, P
    FROELICHER, V
    KLEIN, J
    DETRANO, R
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (09) : 530 - 533
  • [7] CLINICAL-SIGNIFICANCE OF EXERCISE-INDUCED SILENT-MYOCARDIAL-ISCHEMIA IN PATIENTS WITH CORONARY-ARTERY DISEASE
    FALCONE, C
    DESERVI, S
    POMA, E
    CAMPANA, C
    SCIRE, A
    MONTEMARTINI, C
    SPECCHIA, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : 295 - 299
  • [8] EFFECT OF BETA-ADRENOCEPTOR BLOCKADE ON DIPYRIDAMOLE-INDUCED MYOCARDIAL ASYNERGIES IN CORONARY-ARTERY DISEASE
    FERRARA, N
    LONGOBARDI, G
    NICOLINO, A
    ACANFORA, D
    ODIERNA, L
    FURGI, G
    ROSSI, M
    LEOSCO, D
    RENGO, F
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (07) : 724 - 727
  • [9] NONINVASIVE ASSESSMENT OF CORONARY STENOSES BY MYOCARDIAL PERFUSION IMAGING DURING PHARMACOLOGIC CORONARY VASODILATATION .1. PHYSIOLOGIC BASIS AND EXPERIMENTAL VALIDATION
    GOULD, KL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (02) : 267 - 278
  • [10] Josephson R A, 1989, J Am Soc Echocardiogr, V2, P324