DUPLEX-DOPPLER ULTRASONOGRAPHY IN THE ASSESSMENT OF PORTAL-HYPERTENSION - UTILITY OF THE MEASUREMENT OF MAXIMUM PORTAL FLOW VELOCITY

被引:8
作者
DALIMONTE, P [1 ]
CIONI, G [1 ]
CRISTANI, A [1 ]
FERRARI, A [1 ]
VENTURA, E [1 ]
ROMAGNOLI, R [1 ]
机构
[1] UNIV MODENA,DEPT RADIOL,I-41100 MODENA,ITALY
关键词
ULTRASOUND; DUPLEX-DOPPLER ULTRASOUND; PORTAL HYPERTENSION; HYPERTENSION; MEASUREMENT;
D O I
10.1016/0720-048X(93)90049-S
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the utility of Duplex-Doppler ultrasonography (DDUS) in the evaluation of portal haemodynamics we studied 52 patients with compensated liver cirrhosis (mean age 53.9 +/- 9.2 years, males 32, females 20) diagnosed by laparoscopy and biopsy. All patients underwent laparoscopy and oesophageal-gastro-duodenoscopy (OGDS): we postulated that haemodynamically significant portal hypertension (PH) was present if varices were detected at OGDS and/or if collateral veins were revealed at laparoscopy. DDUS was performed with a strictly standardized method and maximum portal flow velocity (PFV) was measured in all patients. Max-PFV ranged between 3.5 and 33.4 cm/s. Overall, 36 patients (69%) had a max-PFV lower than 20.3 cm/s (normal max-PFV range in our laboratory is 20.3-33.3 cm/s), while 16 patients (31%) had normal max-PFV values. Five patients (9.6%) had no sips of PH at laparoscopy and/or OGDS and all five had normal max-PFV values. The other 47 patients (90.4%) had collateral circuli at laparoscopy and 29/47 (61.7%) exhibited also varices at OGDS: max-PFV was lower than 20.3 cm/s in 36/47 patients (76.6%). The measurement of max-PFV demonstrated a 76.6% sensitivity and a 100% specificity in detecting PH, with 100% positive predictive value and 31% negative predictive value. Three patients with PH and apparently normal max-PFV values exhibited a recanalization of the umbilical vein. In conclusion, in cirrhotic patients: (1) a low max-PFV can be considered a sure sign of PH; (2) a normal max-PFV is less probative and may be interpreted in different ways: either (a) portal pressure is really normal or (b) portal pressure is high but collateral circuli originate distally from the sampling volume or (c) a hyperdynamic component exists.
引用
收藏
页码:126 / 129
页数:4
相关论文
共 22 条
[1]  
Podolsky, Isselbaker, Cirrhosis of the liver, Harrison's principles of internal medicine, pp. 1340-1349, (1991)
[2]  
Sherlock, Diseases of the liver and biliary system, (1989)
[3]  
Dagnini, La laparoscopia nella diagnostica clinica, (1978)
[4]  
Burette, De Reuck, Van Gossum, Dumont, Jonas, Deltenre, Evaluation morphologique de l'hypertension portal dans la cirrhose: confrontation laparoscopie oeso-gastroduo-dénoscopie et corrélation avec la pression sinusoidal corrigée, Acta Endoscopica, 15, pp. 131-135, (1985)
[5]  
Dagradi, The natural history of oesophageal varices in patients with alcoholic liver cirrhosis: an endoscopic and clinical study, Am J Med, 57, pp. 520-540, (1972)
[6]  
Becker, Cooperberg, Sonography of the hepatic vascular system, AJR, 150, pp. 999-1005, (1988)
[7]  
Taylor, Burns, Wells, Clinical applications of Doppler ultrasound, (1988)
[8]  
Ohnishi, Saito, Koen, Nakayama, Nomura, Okuda, Pulsed Doppler flow as a criterion of portal venous velocity: comparison with cineangiographic measurements, Radiology, 154, pp. 495-498, (1985)
[9]  
Taylor, Holland, Doppler US. Part I. Basic principles, instrumentation and pitfalls, Radiology, 174, pp. 297-307, (1990)
[10]  
Ohnishi, Nakaiama, Saito, Hatano, Tsukamoto, Terabayashi, Sugita, Wada, Nomura, Koen, Okuda, Effects of propranolol on portal hemodynamics in patients with chronic liver disease, Am J Gastroenterol, 80, pp. 132-135, (1985)