DENSITY, TEMPERATURE, AND POTENTIAL FLUCTUATION MEASUREMENTS BY THE SWEPT LANGMUIR PROBE TECHNIQUE IN WENDELSTEIN 7-AS

被引:42
作者
GIANNONE, L [1 ]
BALBIN, R [1 ]
NIEDERMEYER, H [1 ]
ENDLER, M [1 ]
HERRE, G [1 ]
HIDALGO, C [1 ]
RUDYJ, A [1 ]
THEIMER, G [1 ]
VERPLANKE, P [1 ]
机构
[1] ASSOC EURATOM CIEMAT, E-28040 MADRID, SPAIN
关键词
D O I
10.1063/1.870917
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In the Wendelstein 7-AS stellarator (W7-AS) [Plasma Phys. Controlled Fusion 33, 1591 (1991)], current-voltage characteristics of the Langmuir probe at sweep frequencies in the range 400 kHz to 1 MHz were measured and it was found that the mean and fluctuation values of the ion saturation current, floating potential, and electron temperature were independent of the sweep frequency. A radial scan in the vicinity of the velocity shear layer was performed. The simultaneous sweeping of 3 probe tips showed a statistically significant spatial coherence of the fluctuations in the poloidal direction and a decrease in spatial coherence of the fluctuations with increasing tip separation could be demonstrated. The observation of a change in the propagation direction of fluctuations as the shear layer was crossed and a calculation of the transport spectrum show that the swept probe method is capable of reproducing known results. Apparent temperature fluctuations, due to variations of density and potential during a sweep, are shown by simulations to be only of importance at frequencies above half the Nyquist frequency.