CHRONIC TRAPEZIUS MYALGIA - MORPHOLOGY AND BLOOD-FLOW STUDIED IN 17 PATIENTS

被引:124
作者
LARSSON, SE
BODEGARD, L
HENRIKSSON, KG
OBERG, PA
机构
[1] Linköping University, Department of Orthopedics University Hospital, S-581 85, Linköping
[2] Linköping University, Department of the Neuromuscular Unit, University Hospital, S-581 85, Linköping
[3] Linköping University, Department of Biomedical Engineering, University Hospital, S-581 85, Linköping
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1990年 / 61卷 / 05期
关键词
D O I
10.3109/17453679008993548
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Bilateral open biopsies from the painful upper part of the trapezius muscle were studied in 17 patients with localized chronic myalgia related to static load during repetitive assembly work. Isolated pathologic ragged red fibers were related to the presence of myalgia. the phenomenon indicating disturbed mitochondrial function was confined to the Type 1 fibers. Using a laser-Doppler flowmeter, the muscle blood flow was recorded in the exposed muscle before a biopsy was taken. Pain was assessed and graded as the difference between the two sides, as was the presence of ragged red fibers. the myalgia correlated with reduced local blood flow: the greater the pain difference, the greater the reduction in blood flow. There was a correlation between the presence of mitochondria) changes and reduced muscle blood flow. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 10 条
[1]  
BENGTSSON A, 1986, SCAND J RHEUMATOL, V15, P1
[2]  
HOLMSTROM A, 1983, ACTA CHIR SCAND, V149, P453
[3]  
KVARNSTROM S, 1985, LAKARTIDNINGEN, V82, P1590
[4]   MUSCLE CHANGES IN WORK-RELATED CHRONIC MYALGIA [J].
LARSSON, SE ;
BENGTSSON, A ;
BODEGARD, L ;
HENRIKSSON, KG ;
LARSSON, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (05) :552-556
[5]   NEW INSTRUMENT FOR CONTINUOUS MEASUREMENT OF TISSUE BLOOD-FLOW BY LIGHT BEATING SPECTROSCOPY [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (01) :12-19
[6]   EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) :597-604
[7]  
OBERG PA, 1979, ACTA CHIR SCAND S, V489
[8]  
SALERUD EG, 1987, MED BIOL ENG COMPUT, V25, P329, DOI 10.1007/BF02447433
[9]   LASER DOPPLER BLOOD-FLOW STUDIES DURING OPEN MUSCLE BIOPSY IN PATIENTS WITH NEUROMUSCULAR DISEASES [J].
TAHMOUSH, AJ ;
BOWEN, PD ;
BONNER, RF ;
MANCINI, TJ ;
ENGEL, WK .
NEUROLOGY, 1983, 33 (05) :547-551
[10]  
TYML K, 1985, INT J MICROCIRC, V4, P397