RADIOCONTRAST REMOVAL BY DIALYSIS MEMBRANES

被引:13
作者
GOUGE, SF
MOORE, J
ATKINS, F
HIRSZEL, P
CORY, MJ
机构
[1] UNIFORMED SERV UNIV HLTH SCI,DIV NEPHROL,4301 JONES BRIDGE RD,BETHESDA,MD 20814
[2] WALTER REED ARMY MED CTR,DIV NEPHROL,WASHINGTON,DC 20307
[3] WALTER REED ARMY MED CTR,DEPT CLIN INVEST,WASHINGTON,DC 20307
关键词
CONTRAST MEDIA; HEMODIALYSIS; HEMOFILTRATION;
D O I
10.1159/000170016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To examine the effect of membrane characteristics on radiocontrast mass transfer, we studied in vitro clearances with cuprophane and polyacrylonitrile (PAN) dialyzers and with polysulfone hemofilter. A perfusate of saline at 37-degrees-C, with 7.5 mmol/l (45 mg/dl) of urea and either Renografin (molecular weight 723) or Hexabrix (1405), was pumped through the blood path of dialyzers at 200 ml/min for 5 min. Each radiocontrast agent (RCA) and dialyzer was tested at 0, 150, and 250 or 300 mm Hg transmembrane pressure. In experiments with the use of hemofilter, clearances were tested at the perfusate flow of 50, 100 and 150 ml/min. RCAs were measured by fluorescent excitation analysis of iodine. Mean urea clearance was 16% higher in PAN than in cuprophane dialyzers. Clearance of RCAs was 1.5-3 times higher in PAN than cuprophane dialysers. With the latter, increases in transmembrane pressure resulted in a small amount of ultrafiltration (UF) and little increment in RCA clearance. With the former, increases in transmembrane pressure resulted in massive UF and remarkable increases in RCA clearance. Renografin clearance generally exceeded that of Hexabrix, which we attributed to Renografin's lower molecular weight. With the hemofilter, sieving coefficients were approximately 0.8 for each RCA. Yet, because of the lack of diffusive transport and a small surface area even at the highest perfusate flow rates, RCA clearance by the hemofilter was 20-50% less than that of cuprophane dialyzers. We conclude that PAN dialyzers are more efficient for RCA removal than cuprophane dialyzers or polysulfone hemofilters.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 17 条
  • [1] COMPARISON OF CLEARANCE OF UROGRAPHIC CONTRAST-MEDIUM (SODIUM DIATRIZOATE) BY PERITONEAL AND HEMODIALYSIS
    ACKRILL, P
    MCINTOSH, CS
    NIMMON, C
    BAKER, LRI
    CATTELL, WR
    [J]. CLINICAL SCIENCE AND MOLECULAR MEDICINE, 1976, 50 (01): : 69 - 74
  • [2] RADIOLOGIC CONTRAST-INDUCED NEPHROPATHY
    BERKSETH, RO
    KJELLSTRAND, CM
    [J]. MEDICAL CLINICS OF NORTH AMERICA, 1984, 68 (02) : 351 - 370
  • [3] BERLYNE N, 1962, ACTA MED SCAND, V171, P39
  • [4] NEPHROTOXICITY OF CONTRAST-MEDIA
    BERNS, AS
    KANTER, A
    COHEN, JJ
    GARELLA, S
    SIMON, N
    DUFFY, B
    SPRAGUE, S
    LAU, K
    [J]. KIDNEY INTERNATIONAL, 1989, 36 (04) : 730 - 740
  • [5] RADIOCONTRAST-INDUCED ACUTE RENAL-FAILURE - CLINICAL AND PATHOPHYSIOLOGIC REVIEW
    BYRD, L
    SHERMAN, RL
    [J]. MEDICINE, 1979, 58 (03) : 270 - 279
  • [6] CORONARY-ARTERY BYPASS-SURGERY IN PATIENTS ON CHRONIC-HEMODIALYSIS - A CASE-CONTROL STUDY
    DEUTSCH, E
    BERNSTEIN, RC
    ADDONIZIO, VP
    KUSSMAUL, WG
    [J]. ANNALS OF INTERNAL MEDICINE, 1989, 110 (05) : 369 - 372
  • [7] GAGNON RF, 1985, CLIN NEPHROL, V24, P21
  • [8] HANSSON R, 1963, ACTA MED SCAND, V174, P611
  • [9] KIERDORF H, 1989, ROFO-FORTSCHR RONTG, V128, P119
  • [10] Lasrich M., 1979, ASAIO J, V2, P107