DOSE REQUIREMENTS FOR A NONIONIC CONTRAST AGENT FOR SPIRAL COMPUTED-TOMOGRAPHY OF THE LIVER IN RABBITS

被引:21
作者
BLUEMKE, DA [1 ]
FISHMAN, EK [1 ]
ANDERSON, JH [1 ]
机构
[1] JOHNS HOPKINS MED INST,RUSSELL H MORGAN DEPT RADIOL & RADIOL SCI,BALTIMORE,MD 21205
关键词
COMPUTED TOMOGRAPHY; SPIRAL COMPUTED TOMOGRAPHY; CONTRAST MEDIA; LIVER;
D O I
10.1097/00004424-199402000-00014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The purpose of this study was to determine the relationship between intravenous dose of a nonionic contrast agent and hepatic enhancement using spiral computed tomography. METHODS. The enhancement of the liver, hepatic vein, inferior vena cava, and aorta was evaluated in the New Zealand male rabbit after intravenous injection of iohexol, 300 mg iodine (I)/mL, at 2 mL/sec. Spiral computed tomography scans of 10 animals were evaluated at each of nine different contrast doses (857, 771, 686, 600, 514, 429, 343, 257, and 171 mg I/kg) for a total of 90 spiral scans. RESULTS. Hepatic attenuation was linearly proportional to the contrast dose over the range of doses examined. The average change in attenuation of the liver from the first to the last scanned portion of the liver ranged from 0 to 7 Hounsfield Units (HU) (standard deviation ranging from 4 to 11 HU). Hepatic venous enhancement was greater than that of the liver for doses greater than 171 mg I/mL. The aortocaval difference in enhancement was greater than 10 HU in all cases. CONCLUSION. A dose of 429 mg I/kg, providing an average hepatic enhancement greater than 30 HU, is predicted to be the lower dose limit for hepatic parenchymal enhancement using spiral computed tomography.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 25 条
  • [1] FOCAL HEPATIC MASSES AND FATTY INFILTRATION DETECTED BY ENHANCED DYNAMIC CT
    ALPERN, MB
    LAWSON, TL
    FOLEY, WD
    PERLMAN, SJ
    REIF, LJ
    AREVALOS, E
    RIMM, AA
    [J]. RADIOLOGY, 1986, 158 (01) : 45 - 49
  • [2] SPIRAL CT ARTERIAL PORTOGRAPHY OF THE LIVER
    BLUEMKE, DA
    FISHMAN, EK
    [J]. RADIOLOGY, 1993, 186 (02) : 576 - 579
  • [3] CONTRAST ENHANCEMENT IN ABDOMINAL CT - BOLUS VS INFUSION
    BURGENER, FA
    HAMLIN, DJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) : 351 - 358
  • [4] CONTRAST ENHANCEMENT OF HEPATIC-TUMORS IN CT - COMPARISON BETWEEN BOLUS AND INFUSION TECHNIQUES
    BURGENER, FA
    HAMLIN, DJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (02) : 291 - 295
  • [5] SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY
    COSTELLO, P
    DUPUY, DE
    ECKER, CP
    TELLO, R
    [J]. RADIOLOGY, 1992, 183 (03) : 663 - 666
  • [6] INTRAVENOUS BOLUS OF I125 LABELED MEGLUMINE-DIATRIZOATE - EARLY EXTRAVASCULAR DISTRIBUTION
    DEAN, PB
    KORMANO, M
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1977, 18 (03): : 293 - 304
  • [7] FERRUCCI JT, 1988, RADIOLOGY, V168, P319
  • [8] CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING
    FOLEY, WD
    BERLAND, LL
    LAWSON, TL
    SMITH, DF
    THORSEN, MK
    [J]. RADIOLOGY, 1983, 147 (03) : 797 - 803
  • [9] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [10] ACUTE RENAL DYSFUNCTION IN HIGH-RISK PATIENTS AFTER ANGIOGRAPHY - COMPARISON OF IONIC AND NONIONIC CONTRAST-MEDIA
    GOMES, AS
    LOIS, JF
    BAKER, JD
    MCGLADE, CT
    BUNNELL, DH
    HARTZMAN, S
    [J]. RADIOLOGY, 1989, 170 (01) : 65 - 68