A total of 52 large-scale laboratory pullout and 24 large-scale direct-shear tests were conducted to investigate the interaction behavior between the different reinforcements and cohesive-frictional soil. The reinforcements used were steel grids, bamboo grids, and polymer geogrids. The backfill material used was locally available weathered Bangkok clay. The test results show that the inextensible reinforcements, such as steel grids, move approximately as a rigid body during the pullout test, and the maximum pullout resistance was reached within a relatively small pullout displacement. For extensible reinforcements, such as Tensar geogrids, the degree of resistance mobilization along the reinforcement varies, and the pullout-resistance achieved in the tests was controlled by the stiffness of the reinforcement. For steel grids, the friction resistance from the longitudinal member contributed only to about 10% of the total pullout resistance of the grids. The pullout of the bamboo and Tensar geogrids without transverse members yields 80-90% of the pullout resistance of the corresponding grids with transverse members, attributed to the nodes or ribs on longitudinal members. The bond coefficient as calculated for steel and bamboo grids demonstrated that the steel grids yielded a higher bond coefficient than that of the bamboo grids with the same grid size. However,for a polymer geogrid, the bond coefficient cannot be calculated from a pullout test because of the complicated pullout-resistance-mobilization mechanism along the reinforcement. The large-scale direct-shear-test results showed that, for the soil/grid-reinforcement interfaces, shear resistance can exceed the direct-shear resistance of the soil itself owing to the influence of the apertures on the grids. Finally, for compacted weathered clay, the strength parameters obtained from large-scale direct-shear tests were found to be substantially smaller than the results of triaxial UU tests. This may be because the failure plane in the large-scale direct-shear test was formed progressively, and the peak soil strength along the predetermined shear plane may not have been mobilized simultaneously.
引用
收藏
页码:327 / 349
页数:23
相关论文
共 12 条
[1]  
Abiera, Mechanically stabilized earth using Tensar, bamboo and steel grid reinforcements with weathered Bangkok clay as backfill, M. Eng. thesis, No. GT-90-21, (1991)
[2]  
Bergado, Sampaco, Shivashankar, Alfaro, Anderson, Balasubramaniam, Performance of a welded wire wall with poor quality backfills on soft clay, Proceedings of ASCE 1991 Geotechnical Engineering Congress, pp. 908-922, (1991)
[3]  
Bergado, Hardiyatimo, Cisneros, Chai, Alfaro, Anderson, Pullout resistance of steel geogrid with weathered clay backfill material, Geotech. Testing J., 15, 1, pp. 33-46, (1992)
[4]  
Bergado, Lo, Chai, Shivashankar, Alfaro, Anderson, Pullout tests using steel grid reinforcement with low quality backfill, J. Geotech. Engng. Div., ASCE, 118, 7, pp. 1047-1063, (1992)
[5]  
Chai, Interaction between grid reinforcement and cohesive-frictional soil and performance of reinforced wall/embankment on soft ground, D. Eng. dissertation, (1992)
[6]  
Chang, Hannon, Forsyth, Pull resistance and interaction of earthwork reinforcement and soil, Transportation Res. Rec., 640, pp. 1-7, (1977)
[7]  
Jewell, Milligan, Sarsby, Dubois, Interaction between soil and geogrids, Proceedings of Symposium on Polymer Grid Reinforcement, pp. 18-29, (1984)
[8]  
Ochiai, Hayashi, Othni, Umezaki, Ogisako, Field pullout test of polymer grid in embankment, Proceedings of the International Symposium on Theory and Practice of Earth Reinforcement, pp. 147-151, (1988)
[9]  
Palmeira, Milligan, Scale and other factors affecting the results of pullout tests of grids buried in sand, Geotechnique, 39, pp. 511-524, (1989)
[10]  
Peterson, Anderson, Pullout resistance of welded wire mesh embedded in soil, (1980)