COLONIZATION OF MECHANICAL VENTILATION BAGS DURING USE

被引:1
作者
GAUTHIER, DK
LONG, M
机构
[1] University of Alabama School of Nursing, University of Alabama Hospital, University of Alabama at Birmingham, Birmingham, AL
关键词
D O I
10.1016/0196-6553(94)90035-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Colonization of patients' mechanical ventilation bags was examined to evaluate two criteria (days in use and appearance) for replacing the disposable adapter that interfaces with the patient. Methods: Adapters used 1 to 2, 3 to 4 and 6 to 7 days formed groups I, II, and III, respectively (n = 29 to 67 per group). Another group (IA) contained 33 adapters used 1 to 2 days from patients intubated at least 7 days. Appearance of adapters was noted and adapters were swab cultured on nonselective medium. Results: Analysis of variance indicated a difference in log colony-forming units per adapter between groups I and II (p = 0.032), but colony-forming units per adapter varied widely. Group III had a lower mean colony-forming unit count than group II. Groups I and II differed in variables other than days of use, but these confounding variables were eliminated by substituting group IA for group I. When adapter appearance versus colonization was examined by chi2 test, a significant difference was found between adapters that looked ''clean'' and those with precipitate or with mucus or blood. Conclusions: For the subjects studied, colonization of adapters increased significantly between 1 to 2 and 3 to 4 days of use but varied widely. Appearance may be more useful than days in use as a criterion for changing adapters.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 24 条
[1]  
Horan, White, Jarvis, Et al., Nosocomial infection surveillance, 1984., MMWR CDC Surveill Summ, 35, 1 SS, pp. 17SS-29SS, (1986)
[2]  
Gross, Neu, Aswapokee, Van Antwwerpen, Aswapokee, Deaths from nosocomial infections: experience in a university and a community hospital, Am J Med, 68, pp. 219-223, (1980)
[3]  
Craven, Kunches, Killinsky, Et al., Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation, Am Rev Respir Dis, 133, pp. 792-796, (1986)
[4]  
Wentzel, Hospital-acquired pneumonia: Overview of the current state of the art for prevention and control, European Journal of Clinical Microbiology & Infectious Diseases, 8, pp. 56-60, (1989)
[5]  
Cross, Roup, Role of respiratory assistance devices in endemic nosocomial pneumonia, Am J Med, 70, pp. 681-685, (1981)
[6]  
Haley, Hooton, Culver, Et al., Nosocomial infections in U.S. hospitals, 1975–1976, The American Journal of Medicine, 70, pp. 947-959, (1981)
[7]  
Celis, Torres, Gatell, Et al., Nosocomial pneumonia: a multivariate analysis of risk and prognosis, Chest, 93, pp. 318-324, (1988)
[8]  
LaForce, Lower respiratory tract infections, Hospital infections, pp. 611-639, (1992)
[9]  
Craven, Connolly, Lichtenberg, Primeau, McCabe, Contamination of mechanical ventilators with tubing changes every 24 or 48 hours, N Engl J Med, 306, pp. 1505-1509, (1982)
[10]  
Jay, Nosocomial infections, Med Clin North Am, 67, pp. 1251-1277, (1983)