HUMAN EXPOSURE TO MAGNETIC-FIELDS - A COMPARATIVE-ASSESSMENT OF 2 DOSIMETERS

被引:2
作者
DLUGOSZ, L
BELANGER, K
JOHNSON, P
BRACKEN, MB
机构
[1] YALE UNIV,SCH MED,DEPT EPIDEMIOL & PUBL HLTH,NEW HAVEN,CT 06510
[2] YALE UNIV,SCH MED,DEPT OBSTET & GYNECOL,NEW HAVEN,CT 06510
关键词
MAGNETIC FIELDS; AMEX; AVERAGE MAGNETIC FIELD EXPOSURE SYSTEM;
D O I
10.1002/bem.2250150613
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Two types of dosimeters for measuring human exposure to 60 Hz magnetic fields were compared. Fifty adults wore the single-axis, wrist model AMEX (average magnetic field exposure system) and the triple axis, hip-pocket or pouch model AMEX-3D meters for 2 days. Ninety-six percent of the tests were accomplished without apparent dosimeter failure, The average root mean square magnetic flux density measurements with the AMEX-3D (mean = 0.10 mu T, S.D. = 0.07, range = 0.03 - 0.31) were significantly higher than with the AMEX meter (mean = 0.07 mu T, S.D. 0.05, range 0.02 - 0.27 mu T) (t test, P < 0.01). There was substantial correlation between the AMEX and the AMEX-3D measurements (Pearson's correlation coefficient = 0.65, P < 0.01) but poor concordance (Intraclass correlation coefficient = - 0.25). These results suggest that there is a wide variation in exposure to extremely low frequency magnetic fields in the population. Magnetic field measurements with the AMEX-3D are nearly always higher than with the AMEX dosimeters. Caution is advised when comparing magnetic field measurements made with different types of dosimeters. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:593 / 597
页数:5
相关论文
共 22 条
[1]   INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[2]  
BRACKEN TD, 1993, AM IND HYG ASSOC J, V54, P165, DOI 10.1202/0002-8894(1993)054<0165:EAFPFE>2.0.CO
[3]  
2
[4]   OCCUPATIONAL AND RESIDENTIAL 60-HZ ELECTROMAGNETIC-FIELDS AND HIGH-FREQUENCY ELECTRIC TRANSIENTS - EXPOSURE ASSESSMENT USING A NEW DOSIMETER [J].
DEADMAN, JE ;
CAMUS, M ;
ARMSTRONG, BG ;
HEROUX, P ;
CYR, D ;
PLANTE, M ;
THERIAULT, G .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1988, 49 (08) :409-419
[5]  
ERICSON A, 1986, AM J IND MED, V9, P441
[6]  
ERICSON A, 1986, AM J IND MED, V28, P1226
[7]  
FULTON JP, 1980, AM J EPIDEMIOL, V11, P292
[8]   THE RISK OF MISCARRIAGE AND BIRTH-DEFECTS AMONG WOMEN WHO USE VISUAL-DISPLAY TERMINALS DURING PREGNANCY [J].
GOLDHABER, MK ;
POLEN, MR ;
HIATT, RA .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1988, 13 (06) :695-706
[9]   EXPOSURE TO RESIDENTIAL ELECTRIC AND MAGNETIC-FIELDS AND RISK OF CHILDHOOD LEUKEMIA [J].
LONDON, SJ ;
THOMAS, DC ;
BOWMAN, JD ;
SOBEL, E ;
CHENG, TC ;
PETERS, JM .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1991, 134 (09) :923-937
[10]  
MCDOWALL ME, 1982, LANCET, V1, P246